WR-187 C-band feed

A 4.75 GHz guide carries power through a copper test section.

Readout

Rectangular waveguide modes
TE₁₀ CUTOFF
3.1525GHz
NEXT CUTOFF
6.3049GHz
GUIDE λ
84.375mm
TE IMPEDANCE
503.64Ω
Single-mode safeBetween ideal TE₁₀ and next-mode cutoffs.
Waveguide TE₁₀ live schematicTE₁₀ transverse E-fieldEIA APERTUREa 47.549 mmbb 22.149 mmMode frequency windowGHzOperating 4.75 GHzCutoffSingle modeMultimodeTE₁₀ 3.152 GHzNext 6.305 GHzEVANESCENTTE₁₀ WINDOWHIGHER MODES

Mode thresholds & propagation

QuantityValue
TE₂₀ cutoff6.3049 GHz
TE₀₁ cutoff6.7677 GHz
Phase velocity400.78 Mm/s
Group velocity224.25 Mm/s
Wall attenuation0.035291 dB/m / 0.010757 dB/ft
Ideal air breakdown ceiling4704.9 kW peak

How to read this result

At and below TE₁₀ cutoff, propagating wavelength, velocity, impedance and attenuation are withheld. Above the next cutoff, TE₁₀ values are still reported, with a warning that other modes can propagate.

Cutoffs are ideal uniform-guide values. The single-mode band is the interval between TE₁₀ and the next cutoff, so manufacturer recommended bands are narrower. The dry-air breakdown estimate is a peak-field ceiling, with no operating power rating implied.

Methods & references

Waveguide TE₁₀ examples

All 50 examples