A 10 GHz calibration fixture uses standard air-filled copper waveguide.
WR-90 X-band VNA line
A 10 GHz calibration fixture uses standard air-filled copper waveguide.
Readout
Rectangular waveguide modesMode thresholds & propagation
| Quantity | Value |
|---|---|
| TE₂₀ cutoff | 13.114 GHz |
| TE₀₁ cutoff | 14.754 GHz |
| Phase velocity | 397.07 Mm/s |
| Group velocity | 226.35 Mm/s |
| Wall attenuation | 0.10839 dB/m / 0.033036 dB/ft |
| Ideal air breakdown ceiling | 1047.3 kW peak |
How to read this result
At and below TE₁₀ cutoff, propagating wavelength, velocity, impedance and attenuation are withheld. Above the next cutoff, TE₁₀ values are still reported, with a warning that other modes can propagate.
Cutoffs are ideal uniform-guide values. The single-mode band is the interval between TE₁₀ and the next cutoff, so manufacturer recommended bands are narrower. The dry-air breakdown estimate is a peak-field ceiling, with no operating power rating implied.
Waveguide TE₁₀ examples
All 50 examplesA 4.75 GHz guide carries power through a copper test section.
A 7.2 GHz waveguide section is used in a bench feed with low-loss walls.
A 23.5 GHz guide models a smooth-copper interconnect in a test fixture.
A Ka-band calibration segment is evaluated at 33 GHz before connecting a high-frequency sensor.
A homogeneous dielectric insert lowers the cutoff of a custom 31 × 13 mm aperture.