Outdoor noise setback example

Four plant sources at a construction boundary

Four equal, independent sources contribute sound energy at the boundary. Check how increasing source count changes required setback.

Inputs

Source geometry
Propagation & receiver
Receiver SPL
68.9dB
Setback
116.5m
Air loss
0.33dB
Limit margin
-6.89dB

Source geometry & receiver setback

Illustrative scale
Outdoor source and property-line pathThe path from the selected point or line source is drawn to the receiver. The vertical dashed marker indicates the calculated setback within the schematic scale.POINT SOURCERECEIVERr 55 mSetback 116.5 m68.9 dB
Sound pathReceiverTarget line

Property-line limit exceeded

Limit

The modelled value falls on the wrong side of the entered target.

≥ 3 dB reserve0–3 dB reserveOver limit

Calculation breakdown

Geometrical spreading loss
45.8 dB
Directivity gain
0 dB
Identical-source addition
6.02 dB
Entered property-line limit
62 dB
Setback search result
Solved inside model range