RoomAcousticLab · Calculation record
Outdoor noise setback example
Finite roadway segment
A 70-metre segment is observed at its perpendicular midpoint. Compare the finite-line result with the infinite-line approximation for the same power per metre.
Inputs
- Receiver SPL
- 60.6dB
- Setback
- 37.4m
- Air loss
- 0.05dB
- Limit margin
- -1.56dB
Source geometry & receiver setback
Illustrative scaleProperty-line limit exceeded
LimitThe modelled value falls on the wrong side of the entered target.
≥ 3 dB reserve0–3 dB reserveOver limit
Input snapshot
- Source type
- Finite line
- Sound power per unit length
- 84 dB/m
- Total line length
- 70 m
- Directivity Q
- 1 · Full space
- Identical sources
- 1
- Source addition
- Incoherent · energy
- Receiver distance
- 30 m
- Air attenuation
- 1.5 dB/km
- Property-line limit
- 59 dB
Calculation breakdown
- Geometrical spreading loss
- 23.4 dB
- Directivity gain
- 0 dB
- Identical-source addition
- 0 dB
- Entered property-line limit
- 59 dB
- Setback search result
- Solved inside model range
Setback is solved between 0.1 m and 100 km. This model considers divergence and the entered air loss. A site study can include ground impedance, shielding, weather, reflections, background and source spectra as required by the governing method.