Outdoor noise setback example

Long conveyor line source

Use the long-line approximation for a receiver close to an extended conveyor. Test whether the modelled line-source level clears the entered target.

Inputs

Source geometry
Propagation & receiver
Receiver SPL
63.4dB
Setback
38.7m
Air loss
0.05dB
Limit margin
-3.38dB

Source geometry & receiver setback

Illustrative scale
Outdoor source and property-line pathThe path from the selected point or line source is drawn to the receiver. The vertical dashed marker indicates the calculated setback within the schematic scale.INFINITE LINE SOURCERECEIVERr 18 mSetback 38.7 m63.4 dB
Sound pathReceiverTarget line

Property-line limit exceeded

Limit

The modelled value falls on the wrong side of the entered target.

≥ 3 dB reserve0–3 dB reserveOver limit

Calculation breakdown

Geometrical spreading loss
18.57 dB
Directivity gain
3.01 dB
Identical-source addition
0 dB
Entered property-line limit
60 dB
Setback search result
Solved inside model range