Outdoor noise setback example

Two heat pumps near a wall

Two identical incoherent units share an estimated propagation path. Compare their combined level against the property-line limit.

Inputs

Source geometry
Propagation & receiver
Receiver SPL
63.2dB
Setback
28.3m
Air loss
0dB
Limit margin
-8.21dB

Source geometry & receiver setback

Illustrative scale
Outdoor source and property-line pathThe path from the selected point or line source is drawn to the receiver. The vertical dashed marker indicates the calculated setback within the schematic scale.POINT SOURCERECEIVERr 11 mSetback 28.3 m63.2 dB
Sound pathReceiverTarget line

Property-line limit exceeded

Limit

The modelled value falls on the wrong side of the entered target.

≥ 3 dB reserve0–3 dB reserveOver limit

Calculation breakdown

Geometrical spreading loss
31.82 dB
Directivity gain
6.02 dB
Identical-source addition
3.01 dB
Entered property-line limit
55 dB
Setback search result
Solved inside model range