RoomAcousticLab · Calculation record
Outdoor noise setback example
Four plant sources at a construction boundary
Four equal, independent sources contribute sound energy at the boundary. Check how increasing source count changes required setback.
Inputs
- Receiver SPL
- 68.9dB
- Setback
- 116.5m
- Air loss
- 0.33dB
- Limit margin
- -6.89dB
Source geometry & receiver setback
Illustrative scaleProperty-line limit exceeded
LimitThe modelled value falls on the wrong side of the entered target.
≥ 3 dB reserve0–3 dB reserveOver limit
Input snapshot
- Source type
- Point source
- Sound power Lw
- 109 dB
- Directivity Q
- 1 · Full space
- Identical sources
- 4
- Source addition
- Incoherent · energy
- Receiver distance
- 55 m
- Air attenuation
- 6 dB/km
- Property-line limit
- 62 dB
Calculation breakdown
- Geometrical spreading loss
- 45.8 dB
- Directivity gain
- 0 dB
- Identical-source addition
- 6.02 dB
- Entered property-line limit
- 62 dB
- Setback search result
- Solved inside model range
Setback is solved between 0.1 m and 100 km. This model considers divergence and the entered air loss. A site study can include ground impedance, shielding, weather, reflections, background and source spectra as required by the governing method.