Noise barrier example

Earth berm at high frequency

A tall berm shields an elevated industrial source. The raw estimate can exceed the practical berm cap at this mid-high frequency.

Inputs

Barrier section
Frequency & target
Insertion loss
24dB
Fresnel N
115.638
Path diff.
4.961m
Tip clearance
5.54m

Barrier cross-section & ray paths

Illustrative scale
Noise barrier ray geometryThe indigo sight line joins source and receiver and the teal ray follows the top of the wall or berm. The two horizontal distances and all three heights update with the inputs.SOURCEBERM TIPRECEIVER1.3 m7 m1.7 md₁ 4 md₂ 6 m
DiffractedSight lineBarrier

Practical cap reached

Review

The predicted value has reached the selected barrier type’s cap. Validate end diffraction and transmission.

≥ 2 dB reserveGrazing / reviewBelow target

Calculation breakdown

Source to tip A
6.963 m
Tip to receiver B
8.006 m
Direct path d
10.008 m
Wavelength λ
0.086 m
Diffraction zone
Shadow
Uncapped estimate
33.65 dB
Practical screening cap
24 dB
Target margin
6 dB