RoomAcousticLab · Calculation record
Partition transmission example
Glazed meeting-room partition
A wide glazing band transmits more sound than the adjacent solid wall. Test how the acoustic performance changes with the same glazing area and a better pane.
Inputs
- Composite TL
- 42.3dB
- Wall penalty
- 15.72dB
- Open gap
- 0%
- Target margin
- 1.28dB
Partition elevation & leak response
Illustrative scaleSmall isolation reserve
ReviewThere is less than 3 dB of modelled reserve against the entered target.
≥ 3 dB reserve0–3 dB reserveBelow target
Input snapshot
- Total area
- 30 m²
- Solid wall TL
- 58 dB
- Target TL
- 41 dB
- Weak element
- Glazing
- Element area
- 11 m²
- Element TL
- 38 dB
- Open gap area
- 0 m²
Calculation breakdown
- Solid wall area
- 19 m²
- Weak element share
- 36.667%
- Transmission loss with the gap sealed
- 42.28 dB
- Target band TL
- 41 dB
| Open area | Composite TL | Wall penalty |
|---|---|---|
| 0% | 42.28 dB | 15.717 dB |
| 0.001% | 41.6 dB | 16.396 dB |
| 0.01% | 37.98 dB | 20.017 dB |
| 0.1% | 29.75 dB | 28.249 dB |
| 1% | 19.97 dB | 38.026 dB |
| 5% | 13.01 dB | 44.995 dB |
Matched single-number ratings can provide a rough comparison. A rated composite STC requires a frequency-band TL curve and the ASTM E413 fitting procedure. Treat indirect structure-borne and duct transmission as separate paths.