RoomAcousticLab · Calculation record
Outdoor noise setback example
Long conveyor line source
Use the long-line approximation for a receiver close to an extended conveyor. Test whether the modelled line-source level clears the entered target.
Inputs
- Receiver SPL
- 63.4dB
- Setback
- 38.7m
- Air loss
- 0.05dB
- Limit margin
- -3.38dB
Source geometry & receiver setback
Illustrative scaleProperty-line limit exceeded
LimitThe modelled value falls on the wrong side of the entered target.
≥ 3 dB reserve0–3 dB reserveOver limit
Input snapshot
- Source type
- Infinite line
- Sound power per unit length
- 79 dB/m
- Directivity Q
- 2 · Half space
- Identical sources
- 1
- Source addition
- Incoherent · energy
- Receiver distance
- 18 m
- Air attenuation
- 3 dB/km
- Property-line limit
- 60 dB
Calculation breakdown
- Geometrical spreading loss
- 18.57 dB
- Directivity gain
- 3.01 dB
- Identical-source addition
- 0 dB
- Entered property-line limit
- 60 dB
- Setback search result
- Solved inside model range
Setback is solved between 0.1 m and 100 km. This model considers divergence and the entered air loss. A site study can include ground impedance, shielding, weather, reflections, background and source spectra as required by the governing method.