RoomAcousticLab · Calculation record
Noise barrier example
Low fence in the illuminated zone
The direct ray clears a low fence well above its tip. Check the signed path difference and the model’s roll-off toward zero insertion loss.
Inputs
- Insertion loss
- 0dB
- Fresnel N
- -2.083
- Path diff.
- -0.286m
- Tip clearance
- -1.3m
Barrier cross-section & ray paths
Illustrative scaleInsertion-loss target shortfall
LimitThe modelled value falls on the wrong side of the entered target.
≥ 2 dB reserveGrazing / reviewBelow target
Input snapshot
- Source height
- 2.1 m
- Receiver height
- 2.1 m
- Barrier height
- 0.8 m
- Source to barrier
- 5 m
- Barrier to receiver
- 7 m
- Barrier type
- Thin wall · 20 dB cap
- Band frequency
- 1,250 Hz
- Air temperature
- 20 °C
- Target insertion loss
- 7 dB
Calculation breakdown
- Source to tip A
- 5.166 m
- Tip to receiver B
- 7.12 m
- Direct path d
- 12 m
- Wavelength λ
- 0.275 m
- Diffraction zone
- Illuminated
- Uncapped estimate
- 0 dB
- Practical screening cap
- 20 dB
- Target margin
- -7 dB
The section assumes a continuous, acoustically opaque barrier with one dominant top edge. Finite length, ground effects, reflection and sound through the barrier can change the actual insertion loss.