Partition transmission example

Tiny studio perimeter leak

A pinhole-scale opening makes a small energy contribution relative to an otherwise sealed partition. Check the penalty without rounding it to zero.

Inputs

Primary partition
Weak element & opening
Composite TL
36dB
Wall penalty
4.32e-8dB
Open gap
2.50e-10%
Target margin
6dB

Partition elevation & leak response

Illustrative scale
Partition elevation and transmission loss curveA wall elevation shows the weak element and a visually enlarged gap. The curve plots composite transmission loss against the logarithmic gap share.PARTITION ELEVATIONTL VS OPEN GAP40 m² totalSolid assembly0%5%Current 36 dB
WallWeak elementOpen leak

Transmission target cleared

Pass

The estimate clears the entered target by at least 3 dB.

≥ 3 dB reserve0–3 dB reserveBelow target

Calculation breakdown

Solid wall area
40 m²
Weak element share
0%
Transmission loss with the gap sealed
36 dB
Target band TL
30 dB
Leak area sensitivity
Open areaComposite TLWall penalty
0%36 dB0 dB
2.50e-10%36 dB4.32e-8 dB
0.001%35.83 dB0.17 dB
0.01%34.54 dB1.455 dB
0.1%29.03 dB6.972 dB
1%19.89 dB16.107 dB
5%12.99 dB23.01 dB