RoomAcousticLab · Calculation record
Partition transmission example
Tiny studio perimeter leak
A pinhole-scale opening makes a small energy contribution relative to an otherwise sealed partition. Check the penalty without rounding it to zero.
Inputs
- Composite TL
- 36dB
- Wall penalty
- 4.32e-8dB
- Open gap
- 2.50e-10%
- Target margin
- 6dB
Partition elevation & leak response
Illustrative scaleTransmission target cleared
PassThe estimate clears the entered target by at least 3 dB.
≥ 3 dB reserve0–3 dB reserveBelow target
Input snapshot
- Total area
- 40 m²
- Solid wall TL
- 36 dB
- Target TL
- 30 dB
- Weak element
- Door
- Element area
- 0 m²
- Element TL
- 35 dB
- Open gap area
- 1.00e-10 m²
Calculation breakdown
- Solid wall area
- 40 m²
- Weak element share
- 0%
- Transmission loss with the gap sealed
- 36 dB
- Target band TL
- 30 dB
| Open area | Composite TL | Wall penalty |
|---|---|---|
| 0% | 36 dB | 0 dB |
| 2.50e-10% | 36 dB | 4.32e-8 dB |
| 0.001% | 35.83 dB | 0.17 dB |
| 0.01% | 34.54 dB | 1.455 dB |
| 0.1% | 29.03 dB | 6.972 dB |
| 1% | 19.89 dB | 16.107 dB |
| 5% | 12.99 dB | 23.01 dB |
Matched single-number ratings can provide a rough comparison. A rated composite STC requires a frequency-band TL curve and the ASTM E413 fitting procedure. Treat indirect structure-borne and duct transmission as separate paths.