G6.3 allocation for a fan impeller
A 48 kg rigid fan impeller runs at 1,780 RPM. The balance plan uses equal allocation in two tolerance planes.
Live results
Correction planes & polar vectors- Specific uₚₑᵣ
- 33.798µm
- Total Uₚₑᵣ
- 1,622.3g·mm
- Plane 1 limit
- 811.15g·mm
- Plane 2 limit
- 811.15g·mm
Plane residual screen
Within screenBoth measured residuals are within the entered allocation.
Editable case inputs
Calculation details
| Selected balance grade G | 6.3 mm/s |
|---|---|
| Plane 1 allocation | 50 % |
| Plane 2 allocation | 50 % |
| Plane 1 equivalent mass at radius | 5.79396 g |
| Plane 2 equivalent mass at radius | 5.79396 g |
| Plane 1 measured residual | 760 g·mm |
| Plane 2 measured residual | 520 g·mm |
What to check
Use plane limits rather than total alone. Compare the equivalent grams at the entered 140 mm correction radius.
Model & assumptions
Use maximum service speed and the selected grade for a rigid rotor. Allocate the allowable total with the plane fraction appropriate to the balance arrangement. Select vector trim for a fixed-radius trial with a repeatable phase reference and the same running speed.
ISO 21940-11 continues the rigid-rotor balance framework from ISO 1940-1. Allocate limits using the approved balance plan and verify single-plane trim with an independent post-trim reading. Use machine procedures for trial-weight placement and retention.
Methodology and references ↗RotorVibLab · SI · Engineering calculation
G6.3 allocation for a fan impeller
eₚₑᵣ = 1,000·G/ω · Uₚₑᵣ = M·eₚₑᵣ · α = (V₁−V₀)/Wt · Wc = −V₀/α
Operating inputs
| Calculation | G-grade tolerance |
|---|---|
| Total rotor mass | 48 kg |
| Service speed | 1,780 RPM |
| Balance quality grade G | G6.3 |
| Plane 1 allocation | 50 % |
| Trim radius | 140 mm |
| Plane 1 measured | 760 g·mm |
| Plane 2 measured | 520 g·mm |
Results
| Specific uₚₑᵣ | 33.7981 µm |
|---|---|
| Total Uₚₑᵣ | 1,622.31 g·mm |
| Plane 1 limit | 811.154 g·mm |
| Plane 2 limit | 811.154 g·mm |
| Selected balance grade G | 6.3 mm/s |
| Plane 1 allocation | 50 % |
| Plane 2 allocation | 50 % |
| Plane 1 equivalent mass at radius | 5.79396 g |
| Plane 2 equivalent mass at radius | 5.79396 g |
| Plane 1 measured residual | 760 g·mm |
| Plane 2 measured residual | 520 g·mm |
Plane residual screen. Both measured residuals are within the entered allocation.