RotorVibLab
Menu

Blower trim with a measured post-run result

A blower trial changes the 1× phase across zero. The independent post-trim run reports 0.74 mm/s RMS.

Units
Edit inputs ↓

Live results

Correction planes & polar vectors
Trim angle
78.08°
Model residual
8.043e-15mm/s RMS
Trial change
4.9177mm/s RMS
90°270°180°0°Trial response vectorsInitial V₀8.1 mm/s RMSTrial V₁4.8 mm/s RMSChange ΔV4.918 mm/s RMSTrim mass15.65 gTrim phase78.08 °

Post-trim vibration

Within screen
Residual lowRMS targetAbove target

The measured post-trim reading meets the entered target.

Editable case inputs

Balance method
Single-plane trial run
mm/s RMS
°
g
°
mm/s RMS
°
mm/s RMS
mm/s RMS

Keep the sensor reference, direction of rotation and trial radius the same between runs.

Calculation details

Influence magnitude0.517655 mm/s per g
Influence phase91.9202 °
Measured post-trim RMS0.74 mm/s RMS
Verification target0.8 mm/s RMS

What to check

The displayed model residual follows the linear solution. The measured 0.74 mm/s is what gets compared with the 0.8 mm/s target.

Model & assumptions

eₚₑᵣ = 1,000·G/ω · Uₚₑᵣ = M·eₚₑᵣ · α = (V₁−V₀)/Wt · Wc = −V₀/α

Use maximum service speed and the selected grade for a rigid rotor. Allocate the allowable total with the plane fraction appropriate to the balance arrangement. Select vector trim for a fixed-radius trial with a repeatable phase reference and the same running speed.

ISO 21940-11 continues the rigid-rotor balance framework from ISO 1940-1. Allocate limits using the approved balance plan and verify single-plane trim with an independent post-trim reading. Use machine procedures for trial-weight placement and retention.

Methodology and references ↗