RotorVibLab
Menu

Orthogonal trial vibration response

A controlled trim exercise starts at 3 mm/s at 0°. A 6 g trial at 180° changes the response to 4 mm/s at 90°.

Units
Edit inputs ↓

Live results

Correction planes & polar vectors
Trim angle
233.13°
Model residual
3.032e-15mm/s RMS
Trial change
5mm/s RMS
90°270°180°0°Trial response vectorsInitial V₀3 mm/s RMSTrial V₁4 mm/s RMSChange ΔV5 mm/s RMSTrim mass3.6 gTrim phase233.1 °

Post-trim vibration

Outside screen
Residual lowRMS targetAbove target

The measured post-trim reading exceeds the entered target.

Editable case inputs

Balance method
Single-plane trial run
mm/s RMS
°
g
°
mm/s RMS
°
mm/s RMS
mm/s RMS

Keep the sensor reference, direction of rotation and trial radius the same between runs.

Calculation details

Influence magnitude0.833333 mm/s per g
Influence phase306.87 °
Measured post-trim RMS1.1 mm/s RMS
Verification target0.75 mm/s RMS

What to check

Subtract the complex vectors before calculating influence. The change has magnitude 5 mm/s even though the reading magnitude changed by only 1 mm/s.

Model & assumptions

eₚₑᵣ = 1,000·G/ω · Uₚₑᵣ = M·eₚₑᵣ · α = (V₁−V₀)/Wt · Wc = −V₀/α

Use maximum service speed and the selected grade for a rigid rotor. Allocate the allowable total with the plane fraction appropriate to the balance arrangement. Select vector trim for a fixed-radius trial with a repeatable phase reference and the same running speed.

ISO 21940-11 continues the rigid-rotor balance framework from ISO 1940-1. Allocate limits using the approved balance plan and verify single-plane trim with an independent post-trim reading. Use machine procedures for trial-weight placement and retention.

Methodology and references ↗