RotorVibLab
Menu

G6.3 allocation for a fan impeller

A 48 kg rigid fan impeller runs at 1,780 RPM. The balance plan uses equal allocation in two tolerance planes.

Units
Edit inputs ↓

Live results

Correction planes & polar vectors
Total Uₚₑᵣ
1,622.3g·mm
Plane 1 limit
811.15g·mm
Plane 2 limit
811.15g·mm
Rigid rotorTrim R 140 mmPlane 1Plane 2811.2 g·mm811.2 g·mm

Plane residual screen

Within screen
Within limitPlane limitOver limit

Both measured residuals are within the entered allocation.

Editable case inputs

Balance method
Tolerance & allocation
kg
RPM
%
mm
g·mm
g·mm

Calculation details

Selected balance grade G6.3 mm/s
Plane 1 allocation50 %
Plane 2 allocation50 %
Plane 1 equivalent mass at radius5.79396 g
Plane 2 equivalent mass at radius5.79396 g
Plane 1 measured residual760 g·mm
Plane 2 measured residual520 g·mm

What to check

Use plane limits rather than total alone. Compare the equivalent grams at the entered 140 mm correction radius.

Model & assumptions

eₚₑᵣ = 1,000·G/ω · Uₚₑᵣ = M·eₚₑᵣ · α = (V₁−V₀)/Wt · Wc = −V₀/α

Use maximum service speed and the selected grade for a rigid rotor. Allocate the allowable total with the plane fraction appropriate to the balance arrangement. Select vector trim for a fixed-radius trial with a repeatable phase reference and the same running speed.

ISO 21940-11 continues the rigid-rotor balance framework from ISO 1940-1. Allocate limits using the approved balance plan and verify single-plane trim with an independent post-trim reading. Use machine procedures for trial-weight placement and retention.

Methodology and references ↗