Orthogonal trial vibration response
A controlled trim exercise starts at 3 mm/s at 0°. A 6 g trial at 180° changes the response to 4 mm/s at 90°.
Live results
Correction planes & polar vectors- Trim mass
- 3.6g
- Trim angle
- 233.13°
- Model residual
- 3.032e-15mm/s RMS
- Trial change
- 5mm/s RMS
Post-trim vibration
Outside screenThe measured post-trim reading exceeds the entered target.
Editable case inputs
Calculation details
| Influence magnitude | 0.833333 mm/s per g |
|---|---|
| Influence phase | 306.87 ° |
| Measured post-trim RMS | 1.1 mm/s RMS |
| Verification target | 0.75 mm/s RMS |
What to check
Subtract the complex vectors before calculating influence. The change has magnitude 5 mm/s even though the reading magnitude changed by only 1 mm/s.
Model & assumptions
Use maximum service speed and the selected grade for a rigid rotor. Allocate the allowable total with the plane fraction appropriate to the balance arrangement. Select vector trim for a fixed-radius trial with a repeatable phase reference and the same running speed.
ISO 21940-11 continues the rigid-rotor balance framework from ISO 1940-1. Allocate limits using the approved balance plan and verify single-plane trim with an independent post-trim reading. Use machine procedures for trial-weight placement and retention.
Methodology and references ↗RotorVibLab · SI · Engineering calculation
Orthogonal trial vibration response
eₚₑᵣ = 1,000·G/ω · Uₚₑᵣ = M·eₚₑᵣ · α = (V₁−V₀)/Wt · Wc = −V₀/α
Operating inputs
| Calculation | Single-plane vector trim |
|---|---|
| Initial 1× vibration | 3 mm/s RMS |
| Initial phase | 0 ° |
| Trial mass Wt | 6 g |
| Trial mass angle | 180 ° |
| Trial 1× vibration | 4 mm/s RMS |
| Trial phase | 90 ° |
| Measured post-trim | 1.1 mm/s RMS |
| Post-trim RMS target | 0.75 mm/s RMS |
Results
| Trim mass | 3.6 g |
|---|---|
| Trim angle | 233.13 ° |
| Model residual | 3.0319e-15 mm/s RMS |
| Trial change | 5 mm/s RMS |
| Influence magnitude | 0.833333 mm/s per g |
| Influence phase | 306.87 ° |
| Measured post-trim RMS | 1.1 mm/s RMS |
| Verification target | 0.75 mm/s RMS |
Post-trim vibration. The measured post-trim reading exceeds the entered target.