Blower trim with a measured post-run result
A blower trial changes the 1× phase across zero. The independent post-trim run reports 0.74 mm/s RMS.
Live results
Correction planes & polar vectors- Trim mass
- 15.647g
- Trim angle
- 78.08°
- Model residual
- 8.043e-15mm/s RMS
- Trial change
- 4.9177mm/s RMS
Post-trim vibration
Within screenThe measured post-trim reading meets the entered target.
Editable case inputs
Calculation details
| Influence magnitude | 0.517655 mm/s per g |
|---|---|
| Influence phase | 91.9202 ° |
| Measured post-trim RMS | 0.74 mm/s RMS |
| Verification target | 0.8 mm/s RMS |
What to check
The displayed model residual follows the linear solution. The measured 0.74 mm/s is what gets compared with the 0.8 mm/s target.
Model & assumptions
Use maximum service speed and the selected grade for a rigid rotor. Allocate the allowable total with the plane fraction appropriate to the balance arrangement. Select vector trim for a fixed-radius trial with a repeatable phase reference and the same running speed.
ISO 21940-11 continues the rigid-rotor balance framework from ISO 1940-1. Allocate limits using the approved balance plan and verify single-plane trim with an independent post-trim reading. Use machine procedures for trial-weight placement and retention.
Methodology and references ↗RotorVibLab · SI · Engineering calculation
Blower trim with a measured post-run result
eₚₑᵣ = 1,000·G/ω · Uₚₑᵣ = M·eₚₑᵣ · α = (V₁−V₀)/Wt · Wc = −V₀/α
Operating inputs
| Calculation | Single-plane vector trim |
|---|---|
| Initial 1× vibration | 8.1 mm/s RMS |
| Initial phase | 350 ° |
| Trial mass Wt | 9.5 g |
| Trial mass angle | 45 ° |
| Trial 1× vibration | 4.8 mm/s RMS |
| Trial phase | 24 ° |
| Measured post-trim | 0.74 mm/s RMS |
| Post-trim RMS target | 0.8 mm/s RMS |
Results
| Trim mass | 15.6475 g |
|---|---|
| Trim angle | 78.0798 ° |
| Model residual | 8.0428e-15 mm/s RMS |
| Trial change | 4.91773 mm/s RMS |
| Influence magnitude | 0.517655 mm/s per g |
| Influence phase | 91.9202 ° |
| Measured post-trim RMS | 0.74 mm/s RMS |
| Verification target | 0.8 mm/s RMS |
Post-trim vibration. The measured post-trim reading meets the entered target.