RotorVibLab
Menu

Vibration Isolator Transmissibility Calculator

Find mount natural frequency, static deflection and the transmitted force across resonance and the isolation cutover.

Units
Edit inputs ↓

Live results

Mount response & transmissibility curve
Force ratio
0.11727×
Transmitted
49.255N
Isolation
88.273%
Force ratio TDamping ζ 0.126+101√23.579 rfn 8.491 HzOperating r 3.474

Force isolation cutover

Within screen
Amplificationr = √2Isolation

The mount transmits less force than the input amplitude.

Operating inputs

Mount parameters
kg
N/m
Forcing conditions
Hz
N

Calculation details

Vertical mount stiffness185,000 N/m
Equivalent static deflection3.44558 mm
Forcing frequency29.5 Hz
Equivalent forcing speed1,770 RPM
Frequency ratio r3.47434
Unity-transmissibility cutover12.0078 Hz

Model & assumptions

fn = √(k/m)/(2π) = √(g/δst)/(2π) · r = fd/fn · T = √[(1+(2ζr)²)/((1−r²)²+(2ζr)²)]

Enter the supported mass for one mount and its vertical stiffness or loaded static deflection. For a single harmonic force, transmitted amplitude is T times the excitation. Negative isolation indicates amplification.

This single-mode model assumes a linear spring and viscous damping. At r = √2 the force ratio is unity. Include support flexibility, coupled modes and the start-up speed range when assessing a real installation.