Continuous process water heater
A shell-and-tube unit heats 18,000 lb/hr of process water from 22 °C to 75 °C with a 12% duty margin.
Inputs
Inputs
- Heating mode
- Continuous
- Process fluid flow
- 18,000 lb/hr
- Process fluid heat capacity
- 1 Btu/(lb·°F)
- Inlet or initial temperature
- 71.6 °F
- Outlet or target temperature
- 167 °F
- Heat loss margin
- 12 %
- Valve inlet pressure P₁
- 100 psig
- Condensing pressure P₂
- 25 psig
Calculation results
- Design heating duty
- 1,922,896.51Btu/h
- Process heating duty
- 1,716,871.88Btu/h
- Condensing steam demand
- 2,058.8lb/hr
- Screened trap capacity
- 4,117.6lb/hr
- Trap capacity factor
- 2×
- Required valve Cv
- 11.38Cv
- Required valve Kv
- 9.84Kv
- Valve flow regime
- Choked
- Valve P₂/P₁ absolute
- 34.61%
- Condensing temperature
- 266.76°F
- Steam latent heat
- 934Btu/lb
- Terminal temperature approach
- 99.76°F
Calculation basis
- Continuous or batch heat duty
Q = m·c_p·(T₂ − T₁)·(1 + allowance); m_batch,eq = mass·60/minutes - Steam and trap load
m_steam = Q/h_fg(P₂); m_trap = factor·m_steam - Globe valve coefficient
X = min(0.42, 1 − P₂/P₁); Kv = m_steam/[12·P₁·√(X·(0.84 − X))/0.42]; Cv = 1.156·Kv
Check the original case
Divide the design duty by downstream latent heat. The trap screen uses twice the condensing flow.
- Condensing steam demand2,058.8 lb/hr
- Design heating duty1,922,896.51 Btu/h
- Required valve Cv11.38 Cv
- Screened trap capacity4,117.6 lb/hr
Formulas and assumptions
Continuous or batch heat duty
Q = m·c_p·(T₂ − T₁)·(1 + allowance); m_batch,eq = mass·60/minutes
Use mass per hour for continuous operation or an equivalent hourly batch rate. The target temperature must stay below steam saturation in the exchanger.
Steam and trap load
m_steam = Q/h_fg(P₂); m_trap = factor·m_steam
Use 2× for a continuous screen and 3× for a batch startup screen. Confirm trap capacity at the minimum differential pressure and review exchanger stall.
Globe valve coefficient
X = min(0.42, 1 − P₂/P₁); Kv = m_steam/[12·P₁·√(X·(0.84 − X))/0.42]; Cv = 1.156·Kv
P₁ and P₂ are absolute bar and mass flow is kg/h. This is Spirax Eq. 3.21.2 normalized at zero drop, with choked flow at P₂ ≤ 0.58·P₁. Check valve noise, pressure recovery and capacity with the manufacturer.