Subcritical valve at 15% pressure drop

A process unit throttles saturated steam from approximately 6.0 to 5.1 bar absolute.

Inputs

lb/hr
Btu/(lb·°F)
°F
°F
%
psig
psig
Shell-and-tube steam condensation
Shell-and-tube steam condensationSTEAM FLOW 1,649.6 lb/hr. HEATING DUTY 1.49M Btu/h. VALVE Cv 15.66 Cv. TRAP LOAD 3,299.2 lb/hrSTEAM FLOW1,649.6lb/hrHEATING DUTY1.49MBtu/hVALVE Cv15.66CvTRAP LOAD3,299.2lb/hrSTEAM INCONTROL VALVEPROCESS INPROCESS OUTCONDENSATEValve P₂ / P₁ absoluteSubcritical · 85.03%0%58% critical ratio100%
Live steam / heatCondensate / waterDischarge / loss

Calculation results

Design heating duty
1,493,073.11Btu/h
Process heating duty
1,333,100.99Btu/h
Condensing steam demand
1,649.6lb/hr
Screened trap capacity
3,299.2lb/hr
Trap capacity factor
2×
Required valve Cv
15.66Cv
Required valve Kv
13.55Kv
Valve flow regime
Subcritical
Valve P₂/P₁ absolute
85.03%
Condensing temperature
306.83°F
Steam latent heat
905.1Btu/lb
Terminal temperature approach
76.83°F

Check the original case

The pressure ratio remains above 58%. Read the subcritical valve coefficient and compare it with a lower outlet pressure.

  • Condensing steam demand1,649.6 lb/hr
  • Design heating duty1,493,073.11 Btu/h
  • Required valve Cv15.66 Cv
  • Screened trap capacity3,299.2 lb/hr

Formulas and assumptions

Continuous or batch heat duty

Q = m·c_p·(T₂ − T₁)·(1 + allowance); m_batch,eq = mass·60/minutes

Use mass per hour for continuous operation or an equivalent hourly batch rate. The target temperature must stay below steam saturation in the exchanger.

Steam and trap load

m_steam = Q/h_fg(P₂); m_trap = factor·m_steam

Use 2× for a continuous screen and 3× for a batch startup screen. Confirm trap capacity at the minimum differential pressure and review exchanger stall.

Globe valve coefficient

X = min(0.42, 1 − P₂/P₁); Kv = m_steam/[12·P₁·√(X·(0.84 − X))/0.42]; Cv = 1.156·Kv

P₁ and P₂ are absolute bar and mass flow is kg/h. This is Spirax Eq. 3.21.2 normalized at zero drop, with choked flow at P₂ ≤ 0.58·P₁. Check valve noise, pressure recovery and capacity with the manufacturer.

Worked examples

Open a case to edit its inputs.