8 in header insulation retrofit

A 50 m steam header is evaluated for a 3 in insulation retrofit at 50 °F ambient.

Inputs

lb/hr
psig
ft
ft
Used for heat loss. Equivalent length includes fittings.
in
°F
in
Btu/(h·ft·°F)
Btu/(h·ft²·°F)
Steam header hydraulics and insulation
Steam header hydraulics and insulationVELOCITY 1,848 ft/min. PRESS DROP 0.191 psi. DROP / INLET 0.1 %. INSUL. LOSS 17.71K Btu/hVELOCITY1,848ft/minPRESS DROP0.191psiDROP / INLET0.1%INSUL. LOSS17.71KBtu/hINLETOUTLETNPS 8 · SCH 40BARE LOSSINSULATED256.29K Btu/h17.71K Btu/hSaturated steam velocity screenBelow band04,000 ft/min–6,000 ft/minUpper screen
Live steam / heatCondensate / waterDischarge / loss

Calculation results

Required inlet steam velocity
1,848ft/min
Required inlet velocity, alternate units
9.4m/s
Darcy pressure drop
0.191psi
Drop / inlet absolute pressure
0.1%
Smallest size meeting screens
NPS 5
Velocity screening band
Below band
Actual pipe bore
7.981in
Inlet vapor density
0.4154lb/ft³
Reynolds number
795,271
Darcy friction factor
0.0152
Bare run heat loss
256,291.36Btu/h
Insulated run heat loss
17,709.33Btu/h
Heat loss reduction
238,582.03Btu/h

Check the original case

Compare bare and insulated heat loss, then adjust the material conductivity to test the heat-loss sensitivity.

  • Required inlet steam velocity1,848 ft/min
  • Darcy pressure drop0.191 psi
  • Drop / inlet absolute pressure0.1 %
  • Insulated run heat loss17,709.33 Btu/h

Formulas and assumptions

Flow area and speed

v = (m/3,600)·v_g / (πD_i²/4)

Bores use ASME B36.10 steel pipe dimensions. This sheet uses a 4,000–6,000 ft/min screening band (20.32–30.48 m/s). Spirax discusses a broader 25–40 m/s band and sizing by pressure drop for long runs.

Babcock/Darcy pressure-drop screen

ΔP = f_D·(L_eq/D_i)·ρv²/2

Use inlet saturated density and a vapor-viscosity fit. Darcy friction is 64/Re for laminar flow and Swamee–Jain for turbulent flow, with a transition blend. The suggested minimum size meets the upper speed and 10% absolute-pressure drop screens. Pressure drop is unavailable when the model would exhaust the inlet absolute pressure.

Radial heat loss

q/L = (T_steam − T_air) / [ln(D_2/D_1)/(2πk) + 1/(πD_2h)]

The bare tube uses its outside diameter and zero insulation resistance. The entered film coefficient represents convection and linearized radiation. Heat loss uses physical length.

Worked examples

Open a case to edit its inputs.