Check gross yielding, net tension rupture, and a selected block shear path through a straight bolt grid.
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
ANSI/AISC 360-22B4.3 · D2 · J4.3
Inputs
LRFD
Use loads and strengths from the selected method. Re-enter values after switching methods.
Gusset rupture paths
Within modeled limits
Block shear
167.719kip
Net tension
157.688kip
Gross yield
145.8kip
Net hole
0.875in
Crimson shows the selected block path. Blue marks the gross-width tension section through the last bolt row.
Calculation results
Limit state
Demand
Available
Use
Gross yielding
80 kip
145.8 kip
54.9%
Net tension rupture
80 kip
157.688 kip
50.7%
Block shear rupture
80 kip
167.719 kip
47.7%
Calculation values
Nominal hole diameter
0.813 in
Side edge distance
3 in
Gross tension area Aᵍ
4.5 in²
Net tension area Aₙ
3.625 in²
Effective net area Aₑ
3.625 in²
Block tension area Aₙₜ
1.063 in²
Gross shear area Aᵍᵥ
7.5 in²
Net shear area Aₙᵥ
5.313 in²
Nominal gross yielding
162 kip
Nominal net rupture
210.25 kip
Shear yielding term
162 kip
Shear rupture term
184.875 kip
Block tension term
61.625 kip
Nominal block shear Rₙ
223.625 kip
SteelBeamLab / AISC 360-22 B4.3 · D2 · J4.3
Gusset Plate Block Shear & Net Tension
LRFD · US customary
Use a centered, unstaggered grid with straight load and rupture paths. Assess other plausible paths, gusset stability, and fastener resistance separately.
Entered values
Overall plate width
9 in
Plate thickness t
0.5 in
Steel yield stress Fᵧ
36 ksi
Plate tensile stress Fᵤ
58 ksi
Required tension Pᵣ
80 kip
Nominal bolt diameter
3/4 in
Rows along load
3
Lines across plate
2
Row pitch
3 in
Transverse gage
3 in
Loaded end distance
1.5 in
Block shear path
U path · Two planes
Shear lag factor U
1
Block tension Uᵦₛ
1.0 · Uniform
Key results
Block shear
167.719kip
Net tension
157.688kip
Gross yield
145.8kip
Net hole
0.875in
Limit-state screening
Limit state
Demand
Available
Use
Gross yielding
80 kip
145.8 kip
54.9%
Net tension rupture
80 kip
157.688 kip
50.7%
Block shear rupture
80 kip
167.719 kip
47.7%
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
Calculation basis
Use a centered, unstaggered grid with straight load and rupture paths. Assess other plausible paths, gusset stability, and fastener resistance separately.
Hole and tension areas
For inch-series standard holes, the net deduction is the nominal J3.3 hole diameter plus 1/16 in per B4.3. This is dᵦ + 1/8 in through 7/8-in bolts and dᵦ + 3/16 in for 1-in and larger bolts. Aₑ = UAₙ. D2 compares FᵧAᵍ and FᵤAₑ with their separate design factors.
Block path geometry
The U path runs along both outside bolt lines and across the last row. The edge path runs along one outside bolt line and across the nearest side ligament. Each shear plane deducts n − ½ enlarged holes. The tension path counts half a hole at each intersected end plus whole interior holes.
J4.3 rupture
Rₙ = min(0.60FᵤAₙᵥ, 0.60FᵧAᵍᵥ) + UᵦₛFᵤAₙₜ. Use Uᵦₛ = 1.0 for uniform tension stress or 0.5 for nonuniform stress. Apply φ = 0.75 or Ω = 2.00.