SteelBeamLab

Wide welded box flange in ASD

Use a broad thin top plate between the side walls. Compare the B4.1b flange screen with the allowable plastic reference.

Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.

ANSI/AISC 360-22B4.1b
Design method
Units

Inputs

ASD

Use loads and strengths from the selected method. Re-enter values after switching methods.

Section and load
Box plates

Section and neutral axes

Yield reference
Gross area
45.125in²
Inertia Iₓ
4,337.84in⁴
Plastic Zₓ
403.41in³
Unit weight
153.55lb/ft
Section and neutral axesThe ENA is the elastic centroidal axis. The PNA divides the area in half for uniform material. The lines coincide in symmetric sections.Welded boxView from endDepth 25 inENA = PNAASD yield reference66.57%0%100% limit140%+
The ENA is the elastic centroidal axis. The PNA divides the area in half for uniform material. The lines coincide in symmetric sections.

Calculation results

Limit stateDemandReferenceUse
Plastic yield reference670 kip-ft1,006.512 kip-ft66.6%

Compression element compactness

ElementλλₚλᵣClass
Flange52.57126.97335.884Slender
Web48.2558.281137.274Compact

Calculation values

ENA above bottom
12.5 in
PNA above bottom
12.5 in
Inertia Iᵧ
4,339.26 in⁴
Elastic Sₓ,top
347.027 in³
Elastic Sₓ,bot
347.027 in³
Radius of gyration rₓ
9.805 in
Radius of gyration rᵧ
9.806 in
First yield Mᵧ
1,445.947 kip-ft
Plastic Mₚ
1,680.876 kip-ft
Yield reference · LRFD
1,512.788 kip-ft
Yield reference · ASD
1,006.512 kip-ft

Worked solution at the starting values

  1. Locate the elastic centroid 12.5 in above the bottom. Calculate Iₓ = 4,337.84 in⁴ using parallel axes.
  2. Locate the plastic neutral axis 12.5 in above the bottom and integrate Zₓ = 403.41 in³.
  3. Screen the compression elements. The flange is slender and the web is compact.

Calculation basis

The yield utilization is a reference ceiling. Verify Chapter F local buckling and LTB, shear, welds, stiffeners, and fabrication before sizing a member.

Elastic properties

Decompose the section into rectangular plates with uniform density. Use area-weighted ȳ and the parallel-axis theorem for Iₓ and Iᵧ. Divide Iₓ by the distance to each extreme fiber for Sₓ,top and Sₓ,bot; r = √(I/A).

Plastic neutral axis

Locate the equal-area axis from the bottom by integrating across each plate width. Integrate the first moment of area on both sides of that axis for Zₓ. Unit weight uses 490 lb/ft³ steel density.

Local buckling screen

B4.1b Cases 11, 15, and 16 apply to the selected compression side of a welded I-girder. Cases 19 and 21 apply to a welded box. Check the width/thickness ratio against λₚ and λᵣ. The load comparison uses FᵧZₓ as a reference, with 0.90 or 1/1.67 applied for the selected method.

References and units ↗

More worked examples