Select the smaller bottom flange in compression. Recheck the compression-side web slenderness and flange classification.
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
ANSI/AISC 360-22B4.1b
Inputs
LRFD
Use loads and strengths from the selected method. Re-enter values after switching methods.
Section and neutral axes
Yield reference
Gross area
42.5in²
Inertia Iₓ
10,261.23in⁴
Plastic Zₓ
569in³
Unit weight
144.618lb/ft
The ENA is the elastic centroidal axis. The PNA divides the area in half for uniform material. The lines coincide in symmetric sections.
Calculation results
Limit state
Demand
Reference
Use
Plastic yield reference
1,190 kip-ft
2,133.75 kip-ft
55.8%
Compression element compactness
Element
λ
λₚ
λᵣ
Class
Flange
9
9.152
18.287
Compact
Web
106.153
36.841
137.274
Noncompact
Calculation values
ENA above bottom
27.038 in
PNA above bottom
34 in
Inertia Iᵧ
516.792 in⁴
Elastic Sₓ,top
709.542 in³
Elastic Sₓ,bot
379.508 in³
Radius of gyration rₓ
15.538 in
Radius of gyration rᵧ
3.487 in
First yield Mᵧ
1,581.284 kip-ft
Plastic Mₚ
2,370.833 kip-ft
Yield reference · LRFD
2,133.75 kip-ft
Yield reference · ASD
1,419.661 kip-ft
SteelBeamLab / AISC 360-22 B4.1b
Asymmetric girder in reverse bending
LRFD · US customary
The yield utilization is a reference ceiling. Verify Chapter F local buckling and LTB, shear, welds, stiffeners, and fabrication before sizing a member.
Entered values
Section geometry
Built-up I-girder
Compression face
Bottom flange
Steel yield stress Fᵧ
50 ksi
Required moment Mᵣ
1,190 kip-ft
Top flange width
18 in
Top flange thickness
1 in
Bottom flange width
9 in
Bottom flange thickness
0.5 in
Clear web height h
40 in
Web thickness tᵥ
0.5 in
Key results
Gross area
42.5in²
Inertia Iₓ
10,261.23in⁴
Plastic Zₓ
569in³
Unit weight
144.618lb/ft
Limit-state screening
Limit state
Demand
Reference
Use
Plastic yield reference
1,190 kip-ft
2,133.75 kip-ft
55.8%
Compression element compactness
Element
λ
λₚ
λᵣ
Class
Flange
9
9.152
18.287
Compact
Web
106.153
36.841
137.274
Noncompact
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
Worked solution at the starting values
Locate the elastic centroid 27.038 in above the bottom. Calculate Iₓ = 10,261.23 in⁴ using parallel axes.
Locate the plastic neutral axis 34 in above the bottom and integrate Zₓ = 569 in³.
Screen the compression elements. The flange is compact and the web is noncompact.
Calculation basis
The yield utilization is a reference ceiling. Verify Chapter F local buckling and LTB, shear, welds, stiffeners, and fabrication before sizing a member.
Elastic properties
Decompose the section into rectangular plates with uniform density. Use area-weighted ȳ and the parallel-axis theorem for Iₓ and Iᵧ. Divide Iₓ by the distance to each extreme fiber for Sₓ,top and Sₓ,bot; r = √(I/A).
Plastic neutral axis
Locate the equal-area axis from the bottom by integrating across each plate width. Integrate the first moment of area on both sides of that axis for Zₓ. Unit weight uses 490 lb/ft³ steel density.
Local buckling screen
B4.1b Cases 11, 15, and 16 apply to the selected compression side of a welded I-girder. Cases 19 and 21 apply to a welded box. Check the width/thickness ratio against λₚ and λᵣ. The load comparison uses FᵧZₓ as a reference, with 0.90 or 1/1.67 applied for the selected method.