Section and load
I-girder plates

Section and neutral axes

Yield reference
Gross area
30.25in²
Inertia Iₓ
4,658.4in⁴
Plastic Zₓ
342.797in³
Unit weight
102.934lb/ft
Section and neutral axesThe ENA is the elastic centroidal axis. The PNA divides the area in half for uniform material. The lines coincide in symmetric sections.Built-up I-sectionView from endDepth 31.38 inENAPNALRFD yield reference68.07%0%100% limit140%+
The ENA is the elastic centroidal axis. The PNA divides the area in half for uniform material. The lines coincide in symmetric sections.

Calculation results

Limit stateDemandReferenceUse
Plastic yield reference875 kip-ft1,285.488 kip-ft68.1%

Compression element compactness

ElementλλₚλᵣClass
Flange89.15219.651Compact
Web54.35777.551137.274Compact

Calculation values

ENA above bottom
17.036 in
PNA above bottom
18.375 in
Inertia Iᵧ
160.396 in⁴
Elastic Sₓ,top
324.868 in³
Elastic Sₓ,bot
273.45 in³
Radius of gyration rₓ
12.41 in
Radius of gyration rᵧ
2.303 in
First yield Mᵧ
1,139.376 kip-ft
Plastic Mₚ
1,428.32 kip-ft
Yield reference · LRFD
1,285.488 kip-ft
Yield reference · ASD
855.282 kip-ft

Calculation basis

The yield utilization is a reference ceiling. Verify Chapter F local buckling and LTB, shear, welds, stiffeners, and fabrication before sizing a member.

Elastic properties

Decompose the section into rectangular plates with uniform density. Use area-weighted ȳ and the parallel-axis theorem for Iₓ and Iᵧ. Divide Iₓ by the distance to each extreme fiber for Sₓ,top and Sₓ,bot; r = √(I/A).

Plastic neutral axis

Locate the equal-area axis from the bottom by integrating across each plate width. Integrate the first moment of area on both sides of that axis for Zₓ. Unit weight uses 490 lb/ft³ steel density.

Local buckling screen

B4.1b Cases 11, 15, and 16 apply to the selected compression side of a welded I-girder. Cases 19 and 21 apply to a welded box. Check the width/thickness ratio against λₚ and λᵣ. The load comparison uses FᵧZₓ as a reference, with 0.90 or 1/1.67 applied for the selected method.

References and units ↗

Worked examples