SteelBeamLab

Rectangular base plate on a narrow pedestal

Use unequal plate and pedestal proportions. The narrower pedestal direction sets the largest similar bearing footprint.

Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.

ANSI/AISC 360-22J8 · DG 1
Design method
Units

Inputs

LRFD

Use loads and strengths from the selected method. Re-enter values after switching methods.

Column & load
Steel plate
Concrete pedestal

Base plate plan

Within modeled limits
Bearing P
3,932.228kN
Bearing area
62,034.615mm²
Min. plate t
22.216mm
Gov. length
91.44mm
Base plate planThe dashed rectangle is the 0.95d × 0.80b_f effective column footprint used to measure m and n.Pedestal & plateCentered compressionNBm 85.09 mmn 91.44 mmλn′ 62.88 mmLRFD · Plate thickness69.97%0%100% limit140%+
The dashed rectangle is the 0.95d × 0.80b_f effective column footprint used to measure m and n.

Calculation results

Limit stateDemandAvailableUse
Concrete bearing1,890.494 kN3,932.228 kN48.1%
Plate thickness22.216 mm31.75 mm70%

Calculation values

Plate area A₁
206,451.2 mm²
Similar support area A₂
322,580 mm²
Confinement multiplier
1.25
Applied bearing pressure
9.157 MPa
Projection m
85.09 mm
Projection n
91.44 mm
Inner projection n′
78.801 mm
Yield-line factor λ
0.798
Effective inner λn′
62.878 mm
Nominal concrete bearing
6,049.581 kN
Available bearing · LRFD
3,932.228 kN
Available bearing · ASD
2,618.866 kN

Worked solution at the starting values

  1. Use bearing area 206,451.2 mm² and confinement multiplier 1.25.
  2. Compare m = 85.09 mm, n = 91.44 mm, and λn′ = 62.878 mm.
  3. Use the governing projection to calculate the minimum plate thickness of 22.216 mm.

Calculation basis

For an I-shaped column in centered full-contact compression on a rectangular pedestal. Check the governing concrete code, anchors, grout, welds, and any eccentric load separately.

Concrete confinement

J8 uses 0.85f′cA₁ times the lesser of 2 and √(A₂/A₁). Here A₂ is the largest centered rectangle similar to the plate that fits on the pedestal. Use φc = 0.65 or Ωc = 2.31. The required bearing-only area holds the plate aspect ratio and pedestal fixed.

Plate projection

DG 1 uses m = (N − 0.95d)/2, n = (B − 0.80b_f)/2, and n′ = √(db_f)/4. With X = [4db_f/(d + b_f)²](Pᵣ/available concrete bearing), λ = 2√X/(1 + √(1 − X)), capped at one. The governing projection is the largest of m, n, and λn′.

Thickness

Use tₘᵢₙ = ℓ√[2Pᵣ/(FᵧBN·factor)]. The factor is 0.90 for LRFD and 1/1.67 for ASD. Compare the theoretical minimum to the selected plate thickness and check the concrete bearing separately.

References and units ↗

More worked examples