Place the point load at the free tip of a 7 ft cantilever. Check the fixed-end moment and the total service deflection at the tip.
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
ANSI/AISC 360-22F2 · F7 · G2 · G4
Inputs
LRFD
Use loads and strengths from the selected method. Re-enter values after switching methods.
Span response
Within modeled limits
Peak moment
55.825kip-ft
Peak shear
10.95kip
Total deflect.
0.273in
Available M
97.5kip-ft
Shear and moment use strength loads. The deflected shape uses total service load. Diagram ordinates are independently scaled.
Calculation results
Limit state
Demand
Available
Use
Flexural yielding
55.825 kip-ft
97.5 kip-ft
57.3%
Web shear
10.95 kip
73.44 kip
14.9%
Live deflection
0.222 in
0.233 in
95%
Total deflection
0.273 in
0.35 in
78.1%
Calculation values
Left reaction
10.95 kip
Right reaction
0 kip
Left end moment
-55.825 kip-ft
Live deflection
0.222 in
Plastic moment Mₚ
108.333 kip-ft
First-yield moment Mᵧ
96.667 kip-ft
Nominal shear Vₙ
73.44 kip
Shear area Aᵥ
2.448 in²
h/tw
36.9
Shear coefficient Cᵥ
1
Section inertia Iₓ
118 in⁴
Section yield stress Fᵧ
50 ksi
Flexural compactness
Compact
Available shear · LRFD
73.44 kip
Available shear · ASD
48.96 kip
Available bending · LRFD
97.5 kip-ft
Available bending · ASD
64.87 kip-ft
SteelBeamLab / AISC 360-22 F2 · F7 · G2 · G4
W10×22 cantilever canopy beam
LRFD · US customary
Use a compact, doubly symmetric section with adequate lateral restraint. Check bracing, local loads, load combinations, and project deflection criteria separately.
Entered values
Support condition
Cantilever
Span L
7 ft
Section preset
W10×22
Yield stress Fᵧ
50 ksi
Uniform load w
0.85 kip/ft
Point load P
5 kip
Point location from left
100 %
Dead uniform load
0.34 kip/ft
Live uniform load
0.32 kip/ft
Dead point load
0 kip
Live point load
3 kip
Key results
Peak moment
55.825kip-ft
Peak shear
10.95kip
Total deflect.
0.273in
Available M
97.5kip-ft
Limit-state screening
Limit state
Demand
Available
Use
Flexural yielding
55.825 kip-ft
97.5 kip-ft
57.3%
Web shear
10.95 kip
73.44 kip
14.9%
Live deflection
0.222 in
0.233 in
95%
Total deflection
0.273 in
0.35 in
78.1%
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
Worked solution at the starting values
Resolve the strength-load reactions. The left reaction is 10.95 kip and the right reaction is 0 kip.
Evaluate the peak absolute moment and shear. The demand is 55.825 kip-ft in bending and 10.95 kip in shear.
Integrate the service-load bending diagram with the selected Iₓ. Live deflection is 0.222 in and total deflection is 0.273 in.
Calculation basis
Use a compact, doubly symmetric section with adequate lateral restraint. Check bracing, local loads, load combinations, and project deflection criteria separately.
Span response
Solve beam equilibrium and integrate M/EI over the span. For fixed–pinned support, the right reaction enforces zero vertical movement at the pin. Demand uses the absolute peaks, including the fixed-end region and both sides of the point load.
Flexure and shear
The plastic yielding ceiling is Mₚ = FᵧZₓ. Available bending strength is 0.90Mₚ or Mₚ/1.67 when compactness is satisfied. Web shear is 0.6FᵧAᵥCᵥ. G2 uses Aᵥ = dtw and G4 uses the two clear HSS webs. Rolled I-shapes below the G2.1(a) threshold get φᵥ = 1.00 and Ωᵥ = 1.50. Other supported cases use 0.90 and 1.67.
Serviceability
Enter downward dead and live service loads separately. Include self-weight in the dead case when applicable. Live deflection is checked against L/360 and dead plus live against L/240; project criteria may differ. The model uses linear elastic flexure and neglects shear deformation.