Enter custom section properties for a compact, fully braced welded section. Follow both strength checks and the independent live-load deflection.
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
ANSI/AISC 360-22F2 · F7 · G2 · G4
Inputs
LRFD
Use loads and strengths from the selected method. Re-enter values after switching methods.
Span response
Within modeled limits
Peak moment
94.275kip-ft
Peak shear
17.45kip
Total deflect.
0.374in
Available M
161.573kip-ft
Shear and moment use strength loads. The deflected shape uses total service load. Diagram ordinates are independently scaled.
Calculation results
Limit state
Demand
Available
Use
Flexural yielding
94.275 kip-ft
161.573 kip-ft
58.3%
Web shear
17.45 kip
109.35 kip
16%
Live deflection
0.257 in
0.6 in
42.8%
Total deflection
0.374 in
0.9 in
41.5%
Calculation values
Left reaction
17.45 kip
Right reaction
17.45 kip
Left end moment
0 kip-ft
Live deflection
0.257 in
Plastic moment Mₚ
179.526 kip-ft
First-yield moment Mᵧ
153.06 kip-ft
Nominal shear Vₙ
121.5 kip
Shear area Aᵥ
5.625 in²
h/tw
36
Shear coefficient Cᵥ
1
Section inertia Iₓ
382.65 in⁴
Section yield stress Fᵧ
36 ksi
Flexural compactness
Compact
Available shear · LRFD
109.35 kip
Available shear · ASD
72.754 kip
Available bending · LRFD
161.573 kip-ft
Available bending · ASD
107.501 kip-ft
SteelBeamLab / AISC 360-22 F2 · F7 · G2 · G4
Custom A36 welded I-section beam
LRFD · US customary
Use a compact, doubly symmetric section with adequate lateral restraint. Check bracing, local loads, load combinations, and project deflection criteria separately.
Entered values
Support condition
Simply supported
Span L
18 ft
Section preset
Custom section
Yield stress Fᵧ
36 ksi
Section family
Welded I-section
Overall depth d
15 in
Web / design wall tᵥ
0.375 in
Clear web depth h
13.5 in
Flange width b
8 in
Flange thickness t
0.75 in
Inertia Iₓ
382.65 in⁴
Elastic modulus Sₓ
51.02 in³
Plastic modulus Zₓ
59.842 in³
Uniform load w
1.55 kip/ft
Point load P
7 kip
Point location from left
50 %
Dead uniform load
0.55 kip/ft
Live uniform load
0.85 kip/ft
Dead point load
0 kip
Live point load
4 kip
Key results
Peak moment
94.275kip-ft
Peak shear
17.45kip
Total deflect.
0.374in
Available M
161.573kip-ft
Limit-state screening
Limit state
Demand
Available
Use
Flexural yielding
94.275 kip-ft
161.573 kip-ft
58.3%
Web shear
17.45 kip
109.35 kip
16%
Live deflection
0.257 in
0.6 in
42.8%
Total deflection
0.374 in
0.9 in
41.5%
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
Worked solution at the starting values
Resolve the strength-load reactions. The left reaction is 17.45 kip and the right reaction is 17.45 kip.
Evaluate the peak absolute moment and shear. The demand is 94.275 kip-ft in bending and 17.45 kip in shear.
Integrate the service-load bending diagram with the selected Iₓ. Live deflection is 0.257 in and total deflection is 0.374 in.
Calculation basis
Use a compact, doubly symmetric section with adequate lateral restraint. Check bracing, local loads, load combinations, and project deflection criteria separately.
Span response
Solve beam equilibrium and integrate M/EI over the span. For fixed–pinned support, the right reaction enforces zero vertical movement at the pin. Demand uses the absolute peaks, including the fixed-end region and both sides of the point load.
Flexure and shear
The plastic yielding ceiling is Mₚ = FᵧZₓ. Available bending strength is 0.90Mₚ or Mₚ/1.67 when compactness is satisfied. Web shear is 0.6FᵧAᵥCᵥ. G2 uses Aᵥ = dtw and G4 uses the two clear HSS webs. Rolled I-shapes below the G2.1(a) threshold get φᵥ = 1.00 and Ωᵥ = 1.50. Other supported cases use 0.90 and 1.67.
Serviceability
Enter downward dead and live service loads separately. Include self-weight in the dead case when applicable. Live deflection is checked against L/360 and dead plus live against L/240; project criteria may differ. The model uses linear elastic flexure and neglects shear deformation.