SteelBeamLab

W18×35 office floor beam

Compare the strength and service-load response of a 24 ft simply supported floor beam with a midspan point load.

Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.

ANSI/AISC 360-22F2 · F7 · G2 · G4
Design method
Units

Inputs

LRFD

Use loads and strengths from the selected method. Re-enter values after switching methods.

Span & steel
Strength loads

Enter loads for the selected LRFD or ASD combination.

Percent of span. For a cantilever, measure from the fixed end.
Service loads

All point loads act at the same location. Include member self-weight in dead load.

Span response

Within modeled limits
Peak moment
216kip-ft
Peak shear
30kip
Total deflect.
0.959in
Available M
249.375kip-ft
Span responseShear and moment use strength loads. The deflected shape uses total service load. Diagram ordinates are independently scaled.Span & loadsUDL + point loadVMΔ0L = 24 ftLRFD · Flexural yielding86.62%0%100% limit140%+
Shear and moment use strength loads. The deflected shape uses total service load. Diagram ordinates are independently scaled.

Calculation results

Limit stateDemandAvailableUse
Flexural yielding216 kip-ft249.375 kip-ft86.6%
Web shear30 kip159.3 kip18.8%
Live deflection0.681 in0.8 in85.2%
Total deflection0.959 in1.2 in79.9%

Calculation values

Left reaction
30 kip
Right reaction
30 kip
Left end moment
0 kip-ft
Live deflection
0.681 in
Plastic moment Mₚ
277.083 kip-ft
First-yield moment Mᵧ
240 kip-ft
Nominal shear Vₙ
159.3 kip
Shear area Aᵥ
5.31 in²
h/tw
53.5
Shear coefficient Cᵥ
1
Section inertia Iₓ
510 in⁴
Section yield stress Fᵧ
50 ksi
Flexural compactness
Compact
Available shear · LRFD
159.3 kip
Available shear · ASD
106.2 kip
Available bending · LRFD
249.375 kip-ft
Available bending · ASD
165.918 kip-ft

Worked solution at the starting values

  1. Resolve the strength-load reactions. The left reaction is 30 kip and the right reaction is 30 kip.
  2. Evaluate the peak absolute moment and shear. The demand is 216 kip-ft in bending and 30 kip in shear.
  3. Integrate the service-load bending diagram with the selected Iₓ. Live deflection is 0.681 in and total deflection is 0.959 in.

Calculation basis

Use a compact, doubly symmetric section with adequate lateral restraint. Check bracing, local loads, load combinations, and project deflection criteria separately.

Span response

Solve beam equilibrium and integrate M/EI over the span. For fixed–pinned support, the right reaction enforces zero vertical movement at the pin. Demand uses the absolute peaks, including the fixed-end region and both sides of the point load.

Flexure and shear

The plastic yielding ceiling is Mₚ = FᵧZₓ. Available bending strength is 0.90Mₚ or Mₚ/1.67 when compactness is satisfied. Web shear is 0.6FᵧAᵥCᵥ. G2 uses Aᵥ = dtw and G4 uses the two clear HSS webs. Rolled I-shapes below the G2.1(a) threshold get φᵥ = 1.00 and Ωᵥ = 1.50. Other supported cases use 0.90 and 1.67.

Serviceability

Enter downward dead and live service loads separately. Include self-weight in the dead case when applicable. Live deflection is checked against L/360 and dead plus live against L/240; project criteria may differ. The model uses linear elastic flexure and neglects shear deformation.

References and units ↗

More worked examples