This rolled shape exceeds the G2.1(a) special shear threshold at 50 ksi. Compare its allowable shear with the applied ASD load.
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
ANSI/AISC 360-22F2 · F7 · G2 · G4
Inputs
ASD
Use loads and strengths from the selected method. Re-enter values after switching methods.
Span response
Within modeled limits
Peak moment
251.941kip-ft
Peak shear
36.64kip
Total deflect.
0.677in
Available M
334.331kip-ft
Shear and moment use strength loads. The deflected shape uses total service load. Diagram ordinates are independently scaled.
Calculation results
Limit state
Demand
Available
Use
Flexural yielding
251.941 kip-ft
334.331 kip-ft
75.4%
Web shear
36.64 kip
167.461 kip
21.9%
Live deflection
0.455 in
0.933 in
48.7%
Total deflection
0.677 in
1.4 in
48.3%
Calculation values
Left reaction
36.64 kip
Right reaction
26.56 kip
Left end moment
0 kip-ft
Live deflection
0.455 in
Plastic moment Mₚ
558.333 kip-ft
First-yield moment Mᵧ
475 kip-ft
Nominal shear Vₙ
279.66 kip
Shear area Aᵥ
9.322 in²
h/tw
54.6
Shear coefficient Cᵥ
1
Section inertia Iₓ
1,350 in⁴
Section yield stress Fᵧ
50 ksi
Flexural compactness
Compact
Available shear · LRFD
251.694 kip
Available shear · ASD
167.461 kip
Available bending · LRFD
502.5 kip-ft
Available bending · ASD
334.331 kip-ft
SteelBeamLab / AISC 360-22 F2 · F7 · G2 · G4
W24×55 mezzanine beam in ASD
ASD · US customary
Use a compact, doubly symmetric section with adequate lateral restraint. Check bracing, local loads, load combinations, and project deflection criteria separately.
Entered values
Support condition
Simply supported
Span L
28 ft
Section preset
W24×55
Yield stress Fᵧ
50 ksi
Uniform load w
1.4 kip/ft
Point load P
24 kip
Point location from left
29 %
Dead uniform load
0.63 kip/ft
Live uniform load
0.71 kip/ft
Dead point load
0 kip
Live point load
13 kip
Key results
Peak moment
251.941kip-ft
Peak shear
36.64kip
Total deflect.
0.677in
Available M
334.331kip-ft
Limit-state screening
Limit state
Demand
Available
Use
Flexural yielding
251.941 kip-ft
334.331 kip-ft
75.4%
Web shear
36.64 kip
167.461 kip
21.9%
Live deflection
0.455 in
0.933 in
48.7%
Total deflection
0.677 in
1.4 in
48.3%
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
Worked solution at the starting values
Resolve the strength-load reactions. The left reaction is 36.64 kip and the right reaction is 26.56 kip.
Evaluate the peak absolute moment and shear. The demand is 251.941 kip-ft in bending and 36.64 kip in shear.
Integrate the service-load bending diagram with the selected Iₓ. Live deflection is 0.455 in and total deflection is 0.677 in.
Calculation basis
Use a compact, doubly symmetric section with adequate lateral restraint. Check bracing, local loads, load combinations, and project deflection criteria separately.
Span response
Solve beam equilibrium and integrate M/EI over the span. For fixed–pinned support, the right reaction enforces zero vertical movement at the pin. Demand uses the absolute peaks, including the fixed-end region and both sides of the point load.
Flexure and shear
The plastic yielding ceiling is Mₚ = FᵧZₓ. Available bending strength is 0.90Mₚ or Mₚ/1.67 when compactness is satisfied. Web shear is 0.6FᵧAᵥCᵥ. G2 uses Aᵥ = dtw and G4 uses the two clear HSS webs. Rolled I-shapes below the G2.1(a) threshold get φᵥ = 1.00 and Ωᵥ = 1.50. Other supported cases use 0.90 and 1.67.
Serviceability
Enter downward dead and live service loads separately. Include self-weight in the dead case when applicable. Live deflection is checked against L/360 and dead plus live against L/240; project criteria may differ. The model uses linear elastic flexure and neglects shear deformation.