SteelBeamLab

Steel Beam-Column Axial & Biaxial Interaction

Apply H1-1a or H1-1b to a compression member and optionally amplify first-order non-sway moments by B₁.

Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.

ANSI/AISC 360-22H1-1 · App. 8
Design method
Units

Inputs

LRFD

Use loads and strengths from the selected method. Re-enter values after switching methods.

Demand & analysis
Available strengths

Use available strengths for the selected method.

Normalized P–M envelope

Within modeled limits
H1 unity
0.866
Axial ratio
0.348
Moment sum
0.583
Equation
H1-1a
Normalized P–M envelopeThe horizontal axis combines major- and minor-axis moment ratios. The envelope changes slope at Pᵣ/P_c = 0.20.00.30.30.60.60.90.91.21.2Pᵣ/PcMᵣₓ/Mcₓ + Mᵣᵧ/McᵧH1-1a activeKnee at Pᵣ/Pc = 0.20LRFD · Axial and biaxial bending86.61%0%100% limit140%+
The horizontal axis combines major- and minor-axis moment ratios. The envelope changes slope at Pᵣ/P_c = 0.20.

Calculation results

Limit stateDemandAvailableUse
Axial and biaxial bending0.866186.6%

Calculation values

Major-axis moment ratio
0.423
Minor-axis moment ratio
0.16
Major-axis Mᵣₓ
110 kip-ft
Minor-axis Mᵣᵧ
24 kip-ft

Calculation basis

Provide available member strengths and governing concurrent demands from the same design method. Apply full project stability analysis, including sidesway as required.

Higher axial ratio

At Pᵣ/P_c ≥ 0.20, apply the H1-1a equation Pᵣ/P_c + (8/9)(Mᵣₓ/M_cₓ + Mᵣᵧ/M_cᵧ) ≤ 1.0. Use absolute second-order moments.

Lower axial ratio

At Pᵣ/P_c < 0.20, apply the H1-1b equation Pᵣ/(2P_c) + Mᵣₓ/M_cₓ + Mᵣᵧ/M_cᵧ ≤ 1.0. The two branches meet at normalized moment sum 0.90.

Optional local P–δ

For each axis, B₁ = max[1, Cₘ/(1 − αPᵣ/Pₑ₁)] with α = 1.0 for LRFD or 1.6 for ASD. Enter Pₑ₁ from the applicable non-sway analysis stiffness and effective length. Add any separately amplified sway moment on the same sign convention.

References and units ↗

Worked examples