Combine local B₁ magnification with separately amplified sway moments. The ASD B₁ denominator uses α = 1.6.
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
ANSI/AISC 360-22H1-1 · App. 8
Inputs
ASD
Use loads and strengths from the selected method. Re-enter values after switching methods.
Normalized P–M envelope
Within modeled limits
H1 unity
0.963
Axial ratio
0.341
Moment sum
0.699
Equation
H1-1a
The horizontal axis combines major- and minor-axis moment ratios. The envelope changes slope at Pᵣ/P_c = 0.20.
Calculation results
Limit state
Demand
Available
Use
Axial and biaxial bending
0.963
1
96.3%
Calculation values
Major-axis moment ratio
0.525
Minor-axis moment ratio
0.174
Major-axis Mᵣₓ
135.228 kN·m
Minor-axis Mᵣᵧ
28.389 kN·m
Load factor α
1.6
Major-axis B₁
1.239
Minor-axis B₁
1.297
SteelBeamLab / AISC 360-22 H1-1 · App. 8
ASD beam-column with a separate sway moment
ASD · Metric SI
Provide available member strengths and governing concurrent demands from the same design method. Apply full project stability analysis, including sidesway as required.
Entered values
Moment input
Apply B₁ to non-sway
Compression Pᵣ
622.751 kN
Major-axis moment Mₓ
94.907 kN·m
Minor-axis moment Mᵧ
27.116 kN·m
Compression P_c
1,823.771 kN
Major moment M_cₓ
257.605 kN·m
Minor moment M_cᵧ
162.698 kN·m
Major-axis Cₘ
0.95
Minor-axis Cₘ
0.85
Major-axis Pₑ₁
4,270.293 kN
Minor-axis Pₑ₁
2,891.344 kN
Amplified sway Mₓ
17.626 kN·m
Amplified sway Mᵧ
-6.779 kN·m
Key results
H1 unity
0.963
Axial ratio
0.341
Moment sum
0.699
Equation
H1-1a
Limit-state screening
Limit state
Demand
Available
Use
Axial and biaxial bending
0.963
1
96.3%
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
Worked solution at the starting values
Use B₁ factors 1.239 and 1.297 for the non-sway components.
Calculate Pᵣ/P_c = 0.341 and moment ratio sum 0.699. Apply H1-1a.
Compare unity 0.963 with the interaction limit of 1.0.
Calculation basis
Provide available member strengths and governing concurrent demands from the same design method. Apply full project stability analysis, including sidesway as required.
Higher axial ratio
At Pᵣ/P_c ≥ 0.20, apply the H1-1a equation Pᵣ/P_c + (8/9)(Mᵣₓ/M_cₓ + Mᵣᵧ/M_cᵧ) ≤ 1.0. Use absolute second-order moments.
Lower axial ratio
At Pᵣ/P_c < 0.20, apply the H1-1b equation Pᵣ/(2P_c) + Mᵣₓ/M_cₓ + Mᵣᵧ/M_cᵧ ≤ 1.0. The two branches meet at normalized moment sum 0.90.
Optional local P–δ
For each axis, B₁ = max[1, Cₘ/(1 − αPᵣ/Pₑ₁)] with α = 1.0 for LRFD or 1.6 for ASD. Enter Pₑ₁ from the applicable non-sway analysis stiffness and effective length. Add any separately amplified sway moment on the same sign convention.