SteelBeamLab

ASD beam-column with a separate sway moment

Combine local B₁ magnification with separately amplified sway moments. The ASD B₁ denominator uses α = 1.6.

Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.

ANSI/AISC 360-22H1-1 · App. 8
Design method
Units

Inputs

ASD

Use loads and strengths from the selected method. Re-enter values after switching methods.

Demand & analysis
Available strengths

Use available strengths for the selected method.

B₁ inputs by axis

Supply signed non-sway moments above. Enter any separately amplified sway moments here.

Normalized P–M envelope

Within modeled limits
H1 unity
0.963
Axial ratio
0.341
Moment sum
0.699
Equation
H1-1a
Normalized P–M envelopeThe horizontal axis combines major- and minor-axis moment ratios. The envelope changes slope at Pᵣ/P_c = 0.20.00.30.30.60.60.90.91.21.2Pᵣ/PcMᵣₓ/Mcₓ + Mᵣᵧ/McᵧH1-1a activeKnee at Pᵣ/Pc = 0.20ASD · Axial and biaxial bending96.32%0%100% limit140%+
The horizontal axis combines major- and minor-axis moment ratios. The envelope changes slope at Pᵣ/P_c = 0.20.

Calculation results

Limit stateDemandAvailableUse
Axial and biaxial bending0.963196.3%

Calculation values

Major-axis moment ratio
0.525
Minor-axis moment ratio
0.174
Major-axis Mᵣₓ
135.228 kN·m
Minor-axis Mᵣᵧ
28.389 kN·m
Load factor α
1.6
Major-axis B₁
1.239
Minor-axis B₁
1.297

Worked solution at the starting values

  1. Use B₁ factors 1.239 and 1.297 for the non-sway components.
  2. Calculate Pᵣ/P_c = 0.341 and moment ratio sum 0.699. Apply H1-1a.
  3. Compare unity 0.963 with the interaction limit of 1.0.

Calculation basis

Provide available member strengths and governing concurrent demands from the same design method. Apply full project stability analysis, including sidesway as required.

Higher axial ratio

At Pᵣ/P_c ≥ 0.20, apply the H1-1a equation Pᵣ/P_c + (8/9)(Mᵣₓ/M_cₓ + Mᵣᵧ/M_cᵧ) ≤ 1.0. Use absolute second-order moments.

Lower axial ratio

At Pᵣ/P_c < 0.20, apply the H1-1b equation Pᵣ/(2P_c) + Mᵣₓ/M_cₓ + Mᵣᵧ/M_cᵧ ≤ 1.0. The two branches meet at normalized moment sum 0.90.

Optional local P–δ

For each axis, B₁ = max[1, Cₘ/(1 − αPᵣ/Pₑ₁)] with α = 1.0 for LRFD or 1.6 for ASD. Enter Pₑ₁ from the applicable non-sway analysis stiffness and effective length. Add any separately amplified sway moment on the same sign convention.

References and units ↗