Beam-column at exactly Pᵣ/Pc = 0.20

Set Pᵣ and Pc at an exact fifth. The H1-1a branch applies and the polygon branches meet at normalized moment sum 0.90.

Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.

ANSI/AISC 360-22H1-1 · App. 8
Design method
Units

Inputs

LRFD

Use loads and strengths from the selected method. Re-enter values after switching methods.

Demand & analysis
Available strengths

Use available strengths for the selected method.

Normalized P–M envelope

Within modeled limits
H1 unity
1
Axial ratio
0.2
Moment sum
0.9
Equation
H1-1a
Normalized P–M envelopeThe horizontal axis combines major- and minor-axis moment ratios. The envelope changes slope at Pᵣ/P_c = 0.20.00.30.30.60.60.90.91.21.2Pᵣ/PcMᵣₓ/Mcₓ + Mᵣᵧ/McᵧH1-1a activeKnee at Pᵣ/Pc = 0.20LRFD · Axial and biaxial bending100%0%100% limit140%+
The horizontal axis combines major- and minor-axis moment ratios. The envelope changes slope at Pᵣ/P_c = 0.20.

Calculation results

Limit stateDemandAvailableUse
Axial and biaxial bending11100%

Calculation values

Major-axis moment ratio
0.72
Minor-axis moment ratio
0.18
Major-axis Mᵣₓ
180 kip-ft
Minor-axis Mᵣᵧ
27 kip-ft

Worked solution at the starting values

  1. Use the entered second-order moments.
  2. Calculate Pᵣ/P_c = 0.2 and moment ratio sum 0.9. Apply H1-1a.
  3. Compare unity 1 with the interaction limit of 1.0.

Calculation basis

Provide available member strengths and governing concurrent demands from the same design method. Apply full project stability analysis, including sidesway as required.

Higher axial ratio

At Pᵣ/P_c ≥ 0.20, apply the H1-1a equation Pᵣ/P_c + (8/9)(Mᵣₓ/M_cₓ + Mᵣᵧ/M_cᵧ) ≤ 1.0. Use absolute second-order moments.

Lower axial ratio

At Pᵣ/P_c < 0.20, apply the H1-1b equation Pᵣ/(2P_c) + Mᵣₓ/M_cₓ + Mᵣᵧ/M_cᵧ ≤ 1.0. The two branches meet at normalized moment sum 0.90.

Optional local P–δ

For each axis, B₁ = max[1, Cₘ/(1 − αPᵣ/Pₑ₁)] with α = 1.0 for LRFD or 1.6 for ASD. Enter Pₑ₁ from the applicable non-sway analysis stiffness and effective length. Add any separately amplified sway moment on the same sign convention.