Use a slender weak axis to place the member past the E3 transition. Inspect the 200 screen separately from the computed capacity.
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
ANSI/AISC 360-22E2 · E3
Inputs
LRFD
Use loads and strengths from the selected method. Re-enter values after switching methods.
Column buckling curve
Limit exceeded
Governing KL/r
282.051
Crit. stress
3.155ksi
Available P
25.899kip
Buckling axis
Y
The dot follows the governing KL/r. The E3 branch changes at 4.71√(E/Fᵧ). The preferred slenderness limit is shown at 200.
Calculation results
Limit state
Demand
Available
Use
Flexural buckling
42 kip
25.899 kip
162.2%
KL/r exceeds the AISC preferred screening limit of 200.
Calculation values
Major-axis KL/r
37.5
Minor-axis KL/r
282.051
E3 branch
Elastic
Branch transition
113.432
Euler stress Fₑ
3.598 ksi
Nominal strength Pₙ
28.776 kip
Available compression · LRFD
25.899 kip
Available compression · ASD
17.231 kip
SteelBeamLab / AISC 360-22 E2 · E3
Slender column on the E3 elastic branch
LRFD · US customary
Use nonslender sections. Verify local, torsional and flexural-torsional buckling, frame stability, and effective lengths separately.
Entered values
Unbraced length Lₓ
20 ft
Unbraced length Lᵧ
25 ft
Length factor Kₓ
1
Length factor Kᵧ
1.1
Gross area Aᵍ
9.12 in²
Major-axis radius rₓ
6.4 in
Minor-axis radius rᵧ
1.17 in
Steel yield stress Fᵧ
50 ksi
Required compression Pᵣ
42 kip
Key results
Governing KL/r
282.051
Crit. stress
3.155ksi
Available P
25.899kip
Buckling axis
Y
Limit-state screening
Limit state
Demand
Available
Use
Flexural buckling
42 kip
25.899 kip
162.2%
KL/r exceeds the AISC preferred screening limit of 200.
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
Worked solution at the starting values
Compute KL/r about each axis. The major-axis ratio is 37.5 and the minor-axis ratio is 282.051.
Apply the elastic E3 branch to obtain Fcr = 3.155 ksi.
Multiply the critical stress by gross area and apply the design factor. Available compression is 25.899 kip.
Calculation basis
Use nonslender sections. Verify local, torsional and flexural-torsional buckling, frame stability, and effective lengths separately.
Effective slenderness
For each principal axis, divide effective length KL by radius of gyration r. The larger ratio controls the flexural buckling stress. E2 recommends limiting KL/r to 200 for members designed for compression.
E3 critical stress
Fₑ = π²E/(KL/r)². At KL/r ≤ 4.71√(E/Fᵧ), Fcr = 0.658^(Fᵧ/Fₑ)Fᵧ. Beyond that transition, Fcr = 0.877Fₑ. AISC 360-22 denotes this nominal stress Fₙ.
Available compression
Multiply Fcr by gross area Aᵍ for Pₙ. Available strength is 0.90Pₙ for LRFD or Pₙ/1.67 for ASD. Supply K values from the applicable stability method.