SteelBeamLab

Short rectangular HSS column

Use short lengths and a tube with similar section stiffness about both axes. Assume the HSS walls satisfy the nonslender compression limits.

Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.

ANSI/AISC 360-22E2 · E3
Design method
Units

Inputs

LRFD

Use loads and strengths from the selected method. Re-enter values after switching methods.

Effective length
Section & compression

Column buckling curve

Within modeled limits
Governing KL/r
39.344
Crit. stress
307.846MPa
Available P
1,858.991kN
Buckling axis
Y
Column buckling curveThe dot follows the governing KL/r. The E3 branch changes at 4.71√(E/Fᵧ). The preferred slenderness limit is shown at 200.06086.18120172.4180258.6240344.7Fcr (MPa)KL/rInelasticElastic200 screenLRFD · Flexural buckling71.78%0%100% limit140%+
The dot follows the governing KL/r. The E3 branch changes at 4.71√(E/Fᵧ). The preferred slenderness limit is shown at 200.

Calculation results

Limit stateDemandAvailableUse
Flexural buckling1,334.466 kN1,858.991 kN71.8%

Calculation values

Major-axis KL/r
26.446
Minor-axis KL/r
39.344
E3 branch
Inelastic
Branch transition
113.432
Euler stress Fₑ
1,274.835 MPa
Nominal strength Pₙ
2,065.546 kN
Available compression · LRFD
1,858.991 kN
Available compression · ASD
1,236.854 kN

Worked solution at the starting values

  1. Compute KL/r about each axis. The major-axis ratio is 26.446 and the minor-axis ratio is 39.344.
  2. Apply the inelastic E3 branch to obtain Fcr = 307.846 MPa.
  3. Multiply the critical stress by gross area and apply the design factor. Available compression is 1,858.991 kN.

Calculation basis

Use nonslender sections. Verify local, torsional and flexural-torsional buckling, frame stability, and effective lengths separately.

Effective slenderness

For each principal axis, divide effective length KL by radius of gyration r. The larger ratio controls the flexural buckling stress. E2 recommends limiting KL/r to 200 for members designed for compression.

E3 critical stress

Fₑ = π²E/(KL/r)². At KL/r ≤ 4.71√(E/Fᵧ), Fcr = 0.658^(Fᵧ/Fₑ)Fᵧ. Beyond that transition, Fcr = 0.877Fₑ. AISC 360-22 denotes this nominal stress Fₙ.

Available compression

Multiply Fcr by gross area Aᵍ for Pₙ. Available strength is 0.90Pₙ for LRFD or Pₙ/1.67 for ASD. Supply K values from the applicable stability method.

References and units ↗

More worked examples