Use short lengths and a tube with similar section stiffness about both axes. Assume the HSS walls satisfy the nonslender compression limits.
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
ANSI/AISC 360-22E2 · E3
Inputs
LRFD
Use loads and strengths from the selected method. Re-enter values after switching methods.
Column buckling curve
Within modeled limits
Governing KL/r
39.344
Crit. stress
307.846MPa
Available P
1,858.991kN
Buckling axis
Y
The dot follows the governing KL/r. The E3 branch changes at 4.71√(E/Fᵧ). The preferred slenderness limit is shown at 200.
Calculation results
Limit state
Demand
Available
Use
Flexural buckling
1,334.466 kN
1,858.991 kN
71.8%
Calculation values
Major-axis KL/r
26.446
Minor-axis KL/r
39.344
E3 branch
Inelastic
Branch transition
113.432
Euler stress Fₑ
1,274.835 MPa
Nominal strength Pₙ
2,065.546 kN
Available compression · LRFD
1,858.991 kN
Available compression · ASD
1,236.854 kN
SteelBeamLab / AISC 360-22 E2 · E3
Short rectangular HSS column
LRFD · Metric SI
Use nonslender sections. Verify local, torsional and flexural-torsional buckling, frame stability, and effective lengths separately.
Entered values
Unbraced length Lₓ
2.438 m
Unbraced length Lᵧ
2.438 m
Length factor Kₓ
1
Length factor Kᵧ
1
Gross area Aᵍ
6,709.664 mm²
Major-axis radius rₓ
92.202 mm
Minor-axis radius rᵧ
61.976 mm
Steel yield stress Fᵧ
344.738 MPa
Required compression Pᵣ
1,334.466 kN
Key results
Governing KL/r
39.344
Crit. stress
307.846MPa
Available P
1,858.991kN
Buckling axis
Y
Limit-state screening
Limit state
Demand
Available
Use
Flexural buckling
1,334.466 kN
1,858.991 kN
71.8%
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
Worked solution at the starting values
Compute KL/r about each axis. The major-axis ratio is 26.446 and the minor-axis ratio is 39.344.
Apply the inelastic E3 branch to obtain Fcr = 307.846 MPa.
Multiply the critical stress by gross area and apply the design factor. Available compression is 1,858.991 kN.
Calculation basis
Use nonslender sections. Verify local, torsional and flexural-torsional buckling, frame stability, and effective lengths separately.
Effective slenderness
For each principal axis, divide effective length KL by radius of gyration r. The larger ratio controls the flexural buckling stress. E2 recommends limiting KL/r to 200 for members designed for compression.
E3 critical stress
Fₑ = π²E/(KL/r)². At KL/r ≤ 4.71√(E/Fᵧ), Fcr = 0.658^(Fᵧ/Fₑ)Fᵧ. Beyond that transition, Fcr = 0.877Fₑ. AISC 360-22 denotes this nominal stress Fₙ.
Available compression
Multiply Fcr by gross area Aᵍ for Pₙ. Available strength is 0.90Pₙ for LRFD or Pₙ/1.67 for ASD. Supply K values from the applicable stability method.