Worked example · Hydrology

Commercial parking lot peak runoff

A paved retail parking lot drains through landscaped islands to one downstream inlet. Use the 5.6 in/hr design intensity for the selected duration.

Inputs

Land cover
SurfaceArea (acre)C
Pavement
0–200 acre
0–1
Landscape
0–200 acre
0–1
Open ground
0–200 acre
0–1

Enter area and runoff coefficient for up to three surface categories. Set unused areas to zero.

Design storm
0–25 in/hr

Read intensity for the selected return period and duration from your local IDF data.

Kirpich flow path
10–20,000 ft
0.05–40 %

Use the longest hydraulic channel path and its average grade.

Catchment plan

Live results
Catchment plan Composite runoff estimate. Use rainfall intensity from the local IDF curve at the adopted design duration. PEAK FLOW 15.5 cfs COMPOSITE C 0.796 DRAINAGE AREA 3.45 acre KIRPICH T꜀ 4.15 min DivideOutfallPath · 410 ft 0 · no runoffComposite C1 · full runoff

Composite runoff estimate

Use rainfall intensity from the local IDF curve at the adopted design duration.

Calculation results

Peak flow
15.5 cfs
Composite C
0.796
Drainage area
3.45 acre
Kirpich t꜀
4.15 min
US-equivalent flow factor
1.00833

Worked calculation

Change only the paved area and watch composite C rise. The site outlet still needs its own collection and bypass check.

C = Σ(Aᵢ Cᵢ) / ΣAᵢ · Q = C i A × K · t꜀ = 0.0078 L⁰·⁷⁷ S⁻⁰·³⁸⁵ in minutes with L in ft.

The exact US factor is 121/120 and is displayed as 1.0083. SI uses Q = C i A / 360 with i in mm/hr and A in ha. The rounded US convention uses 1.000. Kirpich estimates the channel travel component. Add sheet and shallow concentrated travel where applicable, and verify local minimum durations and area limits.

Open the main calculator

Share this calculation

This link opens the worksheet with your current inputs and units.