Worked example · Beam analysis
16 ft Garage Opening Double LVL Header Deflection
Use a 16 ft support-center span as a screening case for a double 1¾ × 11⅞ LVL. Enter 120 lb/ft dead and 180 lb/ft live along the entire beam.
Example inputs
Worked result
Updates as you type- Peak bending stress
- 1,400.5 psi
- Total-load deflection
- 0.453 in
- Live-load deflection
- 0.272 in
Beam shear and moment
SchematicProject inputs
- Span between support centers
- 16 ft
- Member preset
- 1¾ × 11⅞ · 2.0E LVL
- Identical side-by-side plies
- 2
- Uniform dead load
- 120 lb/ft
- Uniform live load
- 180 lb/ft
- Dead point load
- 0 lb
- Live point load
- 0 lb
- Point load from left support
- 50%
- Modulus of elasticity E
- 0 psi
- Allowable bending Fb
- 0 psi
- Allowable shear Fv
- 0 psi
Calculation details
- Peak bending stress
- 1,400.5 psi
- Total-load deflection
- 0.453 in
- Live-load deflection
- 0.272 in
- Peak shear stress
- 86.6 psi
- Peak bending moment
- 9,600 lb·ft
- Peak absolute shear
- 2,400 lb
- Left support reaction
- 2,400 lb
- Right support reaction
- 2,400 lb
- Moment of inertia I
- 488.413 in⁴
- Section modulus S
- 82.259 in³
- Total section width
- 3.5 in
- Actual section depth
- 11.875 in
- Modulus E used
- 2,000,000 psi
- Allowable Fb used
- 2,600 psi
- Allowable Fv used
- 285 psi
- Live deflection limit L/360
- 0.533 in
- Total deflection limit L/240
- 0.8 in
Checks and references
- Within limit
Bending Fb
Peak M/S is compared with the entered or preset allowable bending stress.
- Within limit
Shear Fv
Rectangular-section shear uses 1.5V/A and the entered or preset allowable shear stress.
- Within limit
Live load · L/360
The live uniform and point loads are combined before finding peak deflection.
- Within limit
Total load · L/240
This is an immediate elastic deflection screen. Verify the limit and long-term movement for the actual assembly.
- Reference
Beam detailing
Presets use reference values for planning. Verify adjusted design values, bearing, lateral bracing, multi-ply fastening and dead load including beam weight.
Worked calculation
The steps use US customary units for the reference formulas.
Calculate section properties
The modeled section is 3.5 in wide × 11.88 in deep. Use I = bd³/12 = 488.41 in⁴ and S = bd²/6 = 82.26 in³.
Balance the loads
Solve the support reactions from the distributed load and the point load at 50% of span. Left: 2,400 lb. Right: 2,400 lb.
Find peak bending and shear
At the point load and each zero-shear location, evaluate the moment. The peak is 9,600 lb·ft at 8 ft from the left, yielding 1,400.45 psi bending stress.
Add the elastic deflections
Superpose the uniform and point-load curves and find the zero-slope location. Live deflection is 0.272 in and total deflection is 0.453 in.
Enter valid values to see the steps for this layout.
Frequently asked questions
What line load acts on the double LVL in the 16 ft garage example?
The two uniform inputs total 300 lb/ft. Each support takes 2,400 lb in the simply supported model.
How should I measure the span of a garage header at review?