Worked example · Beam analysis

16 ft Garage Opening Double LVL Header Deflection

Use a 16 ft support-center span as a screening case for a double 1¾ × 11⅞ LVL. Enter 120 lb/ft dead and 180 lb/ft live along the entire beam.

Example inputs

Beam and supports
ft
Service loads
lb/ft
lb/ft
lb
lb
%
Adjusted design values
psi
0 uses the preset.
psi
0 uses the preset.
psi
0 uses the preset.
See results

Worked result

Updates as you type
Peak bending stress
1,400.5 psi
Total-load deflection
0.453 in
Live-load deflection
0.272 in

Beam shear and moment

Schematic
Beam shear and moment ShearMoment2,400 lb9,600 lb·ft16 ft

Calculation details

Peak bending stress
1,400.5 psi
Total-load deflection
0.453 in
Live-load deflection
0.272 in
Peak shear stress
86.6 psi
Peak bending moment
9,600 lb·ft
Peak absolute shear
2,400 lb
Left support reaction
2,400 lb
Right support reaction
2,400 lb
Moment of inertia I
488.413 in⁴
Section modulus S
82.259 in³
Total section width
3.5 in
Actual section depth
11.875 in
Modulus E used
2,000,000 psi
Allowable Fb used
2,600 psi
Allowable Fv used
285 psi
Live deflection limit L/360
0.533 in
Total deflection limit L/240
0.8 in

Checks and references

  • Within limit
    Bending Fb

    Peak M/S is compared with the entered or preset allowable bending stress.

  • Within limit
    Shear Fv

    Rectangular-section shear uses 1.5V/A and the entered or preset allowable shear stress.

  • Within limit
    Live load · L/360

    The live uniform and point loads are combined before finding peak deflection.

  • Within limit
    Total load · L/240

    This is an immediate elastic deflection screen. Verify the limit and long-term movement for the actual assembly.

  • Reference
    Beam detailing

    Presets use reference values for planning. Verify adjusted design values, bearing, lateral bracing, multi-ply fastening and dead load including beam weight.

Worked calculation

The steps use US customary units for the reference formulas.

  1. Calculate section properties

    The modeled section is 3.5 in wide × 11.88 in deep. Use I = bd³/12 = 488.41 in⁴ and S = bd²/6 = 82.26 in³.

  2. Balance the loads

    Solve the support reactions from the distributed load and the point load at 50% of span. Left: 2,400 lb. Right: 2,400 lb.

  3. Find peak bending and shear

    At the point load and each zero-shear location, evaluate the moment. The peak is 9,600 lb·ft at 8 ft from the left, yielding 1,400.45 psi bending stress.

  4. Add the elastic deflections

    Superpose the uniform and point-load curves and find the zero-slope location. Live deflection is 0.272 in and total deflection is 0.453 in.

Frequently asked questions

What line load acts on the double LVL in the 16 ft garage example?

The two uniform inputs total 300 lb/ft. Each support takes 2,400 lb in the simply supported model.

How should I measure the span of a garage header at review?

Use the distance between effective bearing centers and verify the actual load path and bearing detail on the plans.

Other calculators