Deck foundations
Deck Post & Footing Load Calculator
Find the load on a deck post and size a round pier from the supported area, local soil capacity, and frost depth.
Project inputs
Results
Updates as you type- Gravity load per post
- 3,200 lb
- Rounded footing diameter screen
- 24 in
- IRC Southern Pine post height
- 14 ft
Tributary area and pier section
SchematicProject inputs
- Tributary width
- 8 ft
- Tributary length
- 8 ft
- Unbraced post height
- 8 ft
- Southern Pine post
- 6 × 6 nominal
- Ground snow load
- 0 psf
- Allowable soil bearing
- 1,500 psf
- Local footing bottom depth
- 36 in
- Selected pier diameter
- 0 in
- Identical piers to pour
- 3
- Effective length factor K
- 1
- Adjusted compression Fc*
- 900 psi
- Adjusted minimum E′min
- 450,000 psi
Calculation details
- Gravity load per post
- 3,200 lb
- Rounded footing diameter screen
- 24 in
- IRC Southern Pine post height
- 14 ft
- Post tributary area
- 64 ft²
- Modeled axial column capacity
- 21,322 lb
- Column slenderness Le/d
- 17.5
- Column stability Cp
- 0.783
- R507.3.1 round footing minimum
- 20 in
- R507.3.1 plain footing thickness
- 7 in
- Diameter for entered soil capacity
- 23.64 in
- Modeled pier diameter
- 24 in
- Gross soil pressure
- 1,469 psf
- Pier bottom below grade
- 36 in
- Concrete per full-depth pier
- 9.425 ft³
- Concrete across all piers
- 1.047 yd³
Checks and references
- Within limit
R507.4 post height
The table screen assumes Southern Pine No. 2 in wet service. Measure from footing top to beam underside.
- Within limit
Axial column stability
The NDS-style stability screen uses K = 1, Le/d ≤ 50 and the adjusted properties entered. Confirm actual restraint and combined loading.
- Within limit
R507.3.1 round footing
The 2021 IRC screen uses the next applicable load band and interpolates within table areas and soil values.
- Within limit
Bearing and post fit
Gross pressure includes 150 lb/ft³ concrete. The footing must support the full square post footprint. Check anchor edge distances separately.
- Reference
Frost protection
Footing bottoms use the larger of 12 in. and the entered local requirement. Confirm frost protection, site soil and footing detail with the local authority.
How the calculation works
The steps use US customary units for the reference formulas.
Find the post tributary load
8 ft × 8 ft = 64 ft². Multiply by 10 psf dead plus the larger of 40 psf live and ground snow for 3,200 lb.
Screen the post as a column
Use effective length K × height and a 5.5 in actual side. Le/d = 17.45. Apply the column stability factor Cp = 0.783 to the adjusted compression stress.
Check the footing diameter
Use R507.3.1 and the entered soil capacity. For the gross-pressure screen, divide post load by soil capacity less the pier self-weight per square foot, then solve the circle area for diameter.
Estimate the pier concrete
A 24 in diameter cylinder to 36 in below grade holds 9.42 ft³ per pier and yields 1,469 psf gross bearing pressure.
Enter valid values to see the steps for this layout.
Frequently asked questions
Can a 4×4 and a 6×6 have different allowable deck post heights?
Yes. R507.4 separates post sizes by species and supported area. The smaller actual side also increases the effective slenderness ratio.
What does the footing diameter include besides supported deck weight?
The round diameter screen includes the IRC table, complete bearing of the post and soil pressure from deck load plus the full cylinder’s concrete weight.