Stair framing
Stair Stringer Rise & Run Calculator
Turn a finished height into equal risers, a tread layout, and a cut list for a straight stair.
Project inputs
Results
Updates as you type- Equal risers
- 5
- Finished rise per step
- 7.2 in
- Total tread run
- 3 ft 4 in
Cut stringer profile
SchematicProject inputs
- Total finished rise
- 36 in
- Tread depth
- 10 in
- Minimum measured headroom
- 82 in
- Sawn stringer stock
- 2 × 12
- Riser count override
- 0
- Finished tread thickness
- 1.5 in
- Blank trim allowance
- 6 in
- Number of stringers
- 3
Calculation details
- Equal risers
- 5
- Finished rise per step
- 7.2 in
- Total tread run
- 3 ft 4 in
- Separate treads
- 4
- Stair pitch
- 35.8°
- Blondel 2R + T
- 24.4 in
- Remaining stringer throat
- 5.41 in
- Estimated blank per stringer
- 4 ft 11.81 in
- Bottom riser layout cut
- 5.7 in
- Stringer blanks to order
- 3
Checks and references
- Within limit
Riser height
2021 IRC R311.7.5.1 limits a typical straight stair riser to 7¾ in. Measure finished elevations.
- Within limit
Tread depth
R311.7.5.2 calls for a 10 in. minimum tread measured between nosings in this layout.
- Within limit
Headroom
Use the smallest vertical clearance above the nosing line or landing. R311.7.2 uses 80 in.
- Within limit
Blondel comfort range
A 24–26 in. band is used here as a stair proportion check.
- Within limit
Cut-stringer throat
AWC DCA 6 Figure 28 uses a 5 in. minimum throat for its cut deck stringer detail.
- Within limit
Cut deck stringer span
DCA 6 Figure 28 uses a 6 ft horizontal span limit for its unsupported cut-stringer detail. Check whether an intermediate support is needed.
- Within limit
Bottom cut
This cut assumes separate tread stock above the cut stringer and a finished lower landing.
- Within limit
Rise between landings
2021 IRC R311.7.3 limits a single flight to 151 in. of vertical rise.
How the calculation works
The steps use US customary units for the reference formulas.
Divide the finished rise
36 in ÷ 5 risers = 7.2 in per riser. Automatic mode rounds up at 7¾ in. per riser.
Set the framing square
Use 7.2 in rise and 10 in run on the square. The upper landing forms the last step, leaving 4 separate treads and 40 in total run.
Check the throat and stair pitch
The notch consumes R × T ÷ √(R² + T²) = 5.84 in measured across the stock. The remaining throat is 5.41 in at 35.75°.
Mark the bottom and estimate stock
Deduct 1.5 in of tread thickness from the bottom rise for a 5.7 in cut. The rise/run diagonal plus 6 in trim allowance calls for 3 blanks of at least 4 ft 11.81 in each.
Enter valid values to see the steps for this layout.
Frequently asked questions
Why is there one fewer separate tread than risers in this layout?
The upper landing is the last step. The separate treads fill the levels between the lower and upper finished surfaces.
Where should I measure the stair headroom input?
Measure vertically at the tightest point from the nosing line or landing surface to the obstruction above. Include the finished surfaces.