Stair framing

Stair Stringer Rise & Run Calculator

Turn a finished height into equal risers, a tread layout, and a cut list for a straight stair.

Project inputs

Finished stair dimensions
in
in
Measured from nosing to nosing.
in
Cut list details
0 uses the automatic count.
in
in
See results

Results

Updates as you type
Equal risers
5
Finished rise per step
7.2 in
Total tread run
3 ft 4 in

Cut stringer profile

Schematic
Cut stringer profile 3 ft3 ft 4 in7.2 in rise × 10 in tread35.8° pitch / 5.41 in throat

Calculation details

Equal risers
5
Finished rise per step
7.2 in
Total tread run
3 ft 4 in
Separate treads
4
Stair pitch
35.8°
Blondel 2R + T
24.4 in
Remaining stringer throat
5.41 in
Estimated blank per stringer
4 ft 11.81 in
Bottom riser layout cut
5.7 in
Stringer blanks to order
3

Checks and references

  • Within limit
    Riser height

    2021 IRC R311.7.5.1 limits a typical straight stair riser to 7¾ in. Measure finished elevations.

  • Within limit
    Tread depth

    R311.7.5.2 calls for a 10 in. minimum tread measured between nosings in this layout.

  • Within limit
    Headroom

    Use the smallest vertical clearance above the nosing line or landing. R311.7.2 uses 80 in.

  • Within limit
    Blondel comfort range

    A 24–26 in. band is used here as a stair proportion check.

  • Within limit
    Cut-stringer throat

    AWC DCA 6 Figure 28 uses a 5 in. minimum throat for its cut deck stringer detail.

  • Within limit
    Cut deck stringer span

    DCA 6 Figure 28 uses a 6 ft horizontal span limit for its unsupported cut-stringer detail. Check whether an intermediate support is needed.

  • Within limit
    Bottom cut

    This cut assumes separate tread stock above the cut stringer and a finished lower landing.

  • Within limit
    Rise between landings

    2021 IRC R311.7.3 limits a single flight to 151 in. of vertical rise.

How the calculation works

The steps use US customary units for the reference formulas.

  1. Divide the finished rise

    36 in ÷ 5 risers = 7.2 in per riser. Automatic mode rounds up at 7¾ in. per riser.

  2. Set the framing square

    Use 7.2 in rise and 10 in run on the square. The upper landing forms the last step, leaving 4 separate treads and 40 in total run.

  3. Check the throat and stair pitch

    The notch consumes R × T ÷ √(R² + T²) = 5.84 in measured across the stock. The remaining throat is 5.41 in at 35.75°.

  4. Mark the bottom and estimate stock

    Deduct 1.5 in of tread thickness from the bottom rise for a 5.7 in cut. The rise/run diagonal plus 6 in trim allowance calls for 3 blanks of at least 4 ft 11.81 in each.

Frequently asked questions

Why is there one fewer separate tread than risers in this layout?

The upper landing is the last step. The separate treads fill the levels between the lower and upper finished surfaces.

Where should I measure the stair headroom input?

Measure vertically at the tightest point from the nosing line or landing surface to the obstruction above. Include the finished surfaces.

Other calculators