Turbo foreline & backing pump / Worked example
Hydrogen Compression Floor in a Turbo Train
A turbopump must hold inlet hydrogen pressure low while a dry pump handles 0.208 Pa·m³/s total foreline load.
Inputs
Compression and foreline gas
Live readout
Backing pressure screen pass- Total foreline throughput
- 0.208 Pa·m³/s
- Estimated foreline pressure
- 69.33 Pa
- Pressure limit with headroom
- 75 Pa
- Compression-limited inlet pressure
- 6.933e-3 Pa
- Backing pressure / maximum
- 69.33%
- Process share of total load
- 86.54%
- Foreline Knudsen number
- 3.967e-3
- Foreline flow regime
- Viscous / continuum
Reading this example
Compare foreline pressure with the operating reserve and compare the compression floor with the inlet target.
Model & assumptions
Foreline balance
Pfore = (Qproc + Qpurge)/Sback,eff
The reserve screen sets a lower operating limit than the maximum backing pressure. Input the effective speed at the foreline port and this pressure range.
Compression floor
Pin,min = Pfore/K₀
Compression is species-specific and depends on operating conditions. This screen applies the entered foreline pressure to the selected species as a worst-case partial pressure. Use measured partial pressure where known.