Turbo foreline & backing pump / Worked example

Nitrogen Purge at Idle

Process flow is off while a small nitrogen purge remains active. The backing pump still runs at 9 L/s.

Readout ↓

Inputs

Backing load and pressure limit
Pa·m³/s
Pa·m³/s
L/s
Pa
%
Compression and foreline gas
mm
°C

Live readout

Backing pressure screen pass
Foreline P2PaReserve limit45PaInlet floor2e-9PaBacking load3.333%PᵢₙChamberK₀TurboPꜰForelineSBackingLog pressure cascadeInlet floor2e-9 PaForeline2 PaMax backing60 PaReserve limit45 PaBacking load3.33%Compression1e9
Total foreline throughput
0.018 Pa·m³/s
Estimated foreline pressure
2 Pa
Pressure limit with headroom
45 Pa
Compression-limited inlet pressure
2e-9 Pa
Backing pressure / maximum
3.333%
Process share of total load
0%
Foreline Knudsen number
0.2149
Foreline flow regime
Transitional flow

    Reading this example

    The purge sets the idle pressure even with zero process load. The process share readout should be zero.

    Model & assumptions

    Foreline balance

    Pfore = (Qproc + Qpurge)/Sback,eff

    The reserve screen sets a lower operating limit than the maximum backing pressure. Input the effective speed at the foreline port and this pressure range.

    Compression floor

    Pin,min = Pfore/K₀