Mean free path & Knudsen number / Worked example
Helium Cryostat Bore
Helium at 80 K and 0.004 Pa moves through a 40 mm bore in a cryostat test fixture.
Inputs
Surface coverage
Live readout
Molecular flow- Mean free path λ
- 919.4 mm
- Knudsen number Kn
- 22.98
- Gas number density
- 3.621e18 m⁻³
- Mean thermal speed
- 650.5 m/s
- Wall impingement flux
- 5.89e20 m⁻² s⁻¹
- Monolayer time
- No sticking
- Molecular below
- 0.1839 Pa
- Continuum above
- 9.194 Pa
Reading this example
Use gas temperature for the mean free path. Thermal speeds differ sharply from a room-temperature nitrogen calibration.
Model & assumptions
Mean free path and regime
λ = kBT / (√2 πd²P) · Kn = λ/D
At Kn below 0.01 use continuum screening. Kn from 0.01 through 0.5 is transitional. Above 0.5, use molecular screening. The transition pressures move with gas temperature, species and channel size.
Wall flux and coverage
n = P/(kBT) · v̄ = √(8RT/πM) · J = nv̄/4 · τ = Nₛ/(sJ)
The Maxwell–Boltzmann mean speed assumes a thermalized ideal gas. The wall flux counts molecular hits. Multiply by the sticking probability to estimate adsorption on an initially clean surface.