Mean free path & Knudsen number / Worked example
Oxygen Plasma Feed Channel
An oxygen feed channel has 3 mm ID at 480 Pa and 80 °C near the plasma source.
Inputs
Surface coverage
Live readout
Viscous / continuum- Mean free path λ
- 0.0191 mm
- Knudsen number Kn
- 6.366e-3
- Gas number density
- 9.845e22 m⁻³
- Mean thermal speed
- 483.4 m/s
- Wall impingement flux
- 1.19e25 m⁻² s⁻¹
- Monolayer time
- 2.101e-6 s
- Molecular below
- 6.111 Pa
- Continuum above
- 305.6 Pa
Reading this example
The nozzle and chamber can be in different flow regimes. This calculation applies to the feed channel at its local pressure.
Model & assumptions
Mean free path and regime
λ = kBT / (√2 πd²P) · Kn = λ/D
At Kn below 0.01 use continuum screening. Kn from 0.01 through 0.5 is transitional. Above 0.5, use molecular screening. The transition pressures move with gas temperature, species and channel size.
Wall flux and coverage
n = P/(kBT) · v̄ = √(8RT/πM) · J = nv̄/4 · τ = Nₛ/(sJ)