Mean free path & Knudsen number / Worked example

UHV Wafer Transfer Chamber

A 160 mm opening joins two wafer transfer modules at 3 × 10⁻⁸ Pa. Estimate nitrogen transport and the time for a clean surface to accumulate a monolayer.

Readout ↓

Inputs

Gas and geometry
Pa
°C
mm
Surface coverage
Enter a probability from 0 to 1.
m⁻²

Live readout

Molecular flow
Mean free path2.292e8mmKnudsen no.1.432e6Thermal speed470.7m/sMonolayer time5.732e4sMolecule pathsD 160 mmLog pressure ladder · Torr1e31e01e-41e-81e-11Continuum >4.3 PaOperating P3e-8 PaMolecular <0.0859 Pa
Mean free path λ
2.292e8 mm
Knudsen number Kn
1.432e6
Gas number density
7.412e12 m⁻³
Mean thermal speed
470.7 m/s
Wall impingement flux
8.722e14 m⁻² s⁻¹
Monolayer time
5.732e4 s
Molecular below
0.08594 Pa
Continuum above
4.297 Pa

    Reading this example

    Use the impingement flux to compare exposure at the transfer pressure. A sticking coefficient below one increases the deposition time.

    Model & assumptions

    Mean free path and regime

    λ = kBT / (√2 πd²P) · Kn = λ/D

    At Kn below 0.01 use continuum screening. Kn from 0.01 through 0.5 is transitional. Above 0.5, use molecular screening. The transition pressures move with gas temperature, species and channel size.

    Wall flux and coverage

    n = P/(kBT) · v̄ = √(8RT/πM) · J = nv̄/4 · τ = Nₛ/(sJ)

    The Maxwell–Boltzmann mean speed assumes a thermalized ideal gas. The wall flux counts molecular hits. Multiply by the sticking probability to estimate adsorption on an initially clean surface.