Mean free path & Knudsen number / Worked example
SF₆ Gauge Capillary
A 0.8 mm capillary connects an SF₆ instrument to a 13 Pa gas space. Screen the transport regime in the capillary.
Inputs
Surface coverage
Live readout
Transitional flow- Mean free path λ
- 0.234 mm
- Knudsen number Kn
- 0.2925
- Gas number density
- 3.179e21 m⁻³
- Mean thermal speed
- 207.2 m/s
- Wall impingement flux
- 1.647e23 m⁻² s⁻¹
- Monolayer time
- 6.072e-5 s
- Molecular below
- 7.606 Pa
- Continuum above
- 380.3 Pa
Reading this example
Local capillary geometry matters more than chamber diameter for the Knudsen classification at the sensor inlet.
Model & assumptions
Mean free path and regime
λ = kBT / (√2 πd²P) · Kn = λ/D
At Kn below 0.01 use continuum screening. Kn from 0.01 through 0.5 is transitional. Above 0.5, use molecular screening. The transition pressures move with gas temperature, species and channel size.
Wall flux and coverage
n = P/(kBT) · v̄ = √(8RT/πM) · J = nv̄/4 · τ = Nₛ/(sJ)
The Maxwell–Boltzmann mean speed assumes a thermalized ideal gas. The wall flux counts molecular hits. Multiply by the sticking probability to estimate adsorption on an initially clean surface.