Mean free path & Knudsen number / Worked example

SF₆ Gauge Capillary

A 0.8 mm capillary connects an SF₆ instrument to a 13 Pa gas space. Screen the transport regime in the capillary.

Readout ↓

Inputs

Gas and geometry
Pa
°C
mm
Surface coverage
Enter a probability from 0 to 1.
m⁻²

Live readout

Transitional flow
Mean free path0.234mmKnudsen no.0.2925Thermal speed207.2m/sMonolayer time6.072e-5sMolecule pathsD 0.8 mmLog pressure ladder · Torr1e31e01e-41e-81e-11Continuum >380 PaOperating P13 PaMolecular <7.61 Pa
Mean free path λ
0.234 mm
Knudsen number Kn
0.2925
Gas number density
3.179e21 m⁻³
Mean thermal speed
207.2 m/s
Wall impingement flux
1.647e23 m⁻² s⁻¹
Monolayer time
6.072e-5 s
Molecular below
7.606 Pa
Continuum above
380.3 Pa

    Reading this example

    Local capillary geometry matters more than chamber diameter for the Knudsen classification at the sensor inlet.

    Model & assumptions

    Mean free path and regime

    λ = kBT / (√2 πd²P) · Kn = λ/D

    At Kn below 0.01 use continuum screening. Kn from 0.01 through 0.5 is transitional. Above 0.5, use molecular screening. The transition pressures move with gas temperature, species and channel size.

    Wall flux and coverage

    n = P/(kBT) · v̄ = √(8RT/πM) · J = nv̄/4 · τ = Nₛ/(sJ)