Mean free path & Knudsen number / Worked example
Water Vapor in a Load Lock
A recently opened load lock is pumping through 0.09 Pa. Estimate the water vapor impingement rate at a 95 mm characteristic dimension.
Inputs
Surface coverage
Live readout
Molecular flow- Mean free path λ
- 149.1 mm
- Knudsen number Kn
- 1.569
- Gas number density
- 2.15e19 m⁻³
- Mean thermal speed
- 596.9 m/s
- Wall impingement flux
- 3.209e21 m⁻² s⁻¹
- Monolayer time
- 5.194e-3 s
- Molecular below
- 0.2824 Pa
- Continuum above
- 14.12 Pa
Reading this example
A high wall flux signals frequent impacts. Coverage still depends on temperature, adsorption chemistry and the actual partial pressure.
Model & assumptions
Mean free path and regime
λ = kBT / (√2 πd²P) · Kn = λ/D
At Kn below 0.01 use continuum screening. Kn from 0.01 through 0.5 is transitional. Above 0.5, use molecular screening. The transition pressures move with gas temperature, species and channel size.
Wall flux and coverage
n = P/(kBT) · v̄ = √(8RT/πM) · J = nv̄/4 · τ = Nₛ/(sJ)
The Maxwell–Boltzmann mean speed assumes a thermalized ideal gas. The wall flux counts molecular hits. Multiply by the sticking probability to estimate adsorption on an initially clean surface.