Pipe conductance & pump speed / Worked example
Transitional Deposition Exhaust
An argon deposition line runs at mean pressure 0.8 Pa with a 32 mm diameter and 18 cm straight run.
Inputs
Gas and series restriction
Live readout
Transitional flow- Molecular conductance
- 15.19 L/s
- Laminar conductance model
- 5.129 L/s
- Molecular transmission
- 19.16%
- Knudsen number Kn
- 0.3078
- Regime-adjusted tube conductance
- 13.94 L/s
- Total series conductance
- 13.94 L/s
- Effective chamber speed
- 12.16 L/s
- Pump utilization
- 12.8%
- Minimum inside diameter for 80%
- 98.82 mm
Reading this example
Compare the two limiting conductances before relying on the transition blend. A measured speed curve gives better process accuracy.
Model & assumptions
Tube throughput
Cₘ = (A v̄/4) / (1 + 3L/4D) · Cᵥ = πD⁴P̄/(128ηL)
The aperture-to-long-tube resistance approximation approaches Clausing’s long-tube limit. It is a simplified short-tube correction. The viscous model assumes isothermal, fully developed laminar flow.
Chamber speed
1/Cₜ = 1/C + 1/C₂ · 1/Sₑ = 1/Sₚ + 1/Cₜ
Transition uses a logarithmic Knudsen weight between the two limits. The 80% search requires Cₜ ≥ 4Sₚ. A fixed series restriction at or below 4Sₚ makes the 80% target unattainable by enlarging the tube alone.