Pipe conductance & pump speed / Worked example

Wafer Transfer Turbo Line

A 300 L/s turbopump is connected through 0.45 m of 63 mm bore pipe at 0.002 Pa.

Readout ↓

Inputs

Tube and pump
mm
m
Use zero for a thin aperture in molecular flow.
L/s
Pa
Gas and series restriction
°C
L/s
Enter 0 to omit a valve, baffle or other restriction.

Live readout

Molecular flow
Tube C56.75L/sChamber speed47.72L/sUtilization15.91%ID for 80%191.1mmChamberTubePumpID 63 mmChamber speed · L/s vs ID · mm01503000107214FlowMolecularPump speed300 L/s80% target240 L/s
Molecular conductance
56.75 L/s
Laminar conductance model
0.09478 L/s
Molecular transmission
15.73%
Knudsen number Kn
54.27
Regime-adjusted tube conductance
56.75 L/s
Total series conductance
56.75 L/s
Effective chamber speed
47.72 L/s
Pump utilization
15.91%
Minimum inside diameter for 80%
191.1 mm

    Reading this example

    Compare the chamber-effective speed with nameplate speed. Increasing tube ID often has more effect here than changing pumps.

    Model & assumptions

    Tube throughput

    Cₘ = (A v̄/4) / (1 + 3L/4D) · Cᵥ = πD⁴P̄/(128ηL)

    The aperture-to-long-tube resistance approximation approaches Clausing’s long-tube limit. It is a simplified short-tube correction. The viscous model assumes isothermal, fully developed laminar flow.

    Chamber speed

    1/Cₜ = 1/C + 1/C₂ · 1/Sₑ = 1/Sₚ + 1/Cₜ

    Transition uses a logarithmic Knudsen weight between the two limits. The 80% search requires Cₜ ≥ 4Sₚ. A fixed series restriction at or below 4Sₚ makes the 80% target unattainable by enlarging the tube alone.