Pipe conductance & pump speed / Worked example

Viscous Dry Pump Header

A 22 mm tube carries air at mean pressure 350 Pa over 0.85 m to a dry pump.

Readout ↓

Inputs

Tube and pump
mm
m
Use zero for a thin aperture in molecular flow.
L/s
Pa
Gas and series restriction
°C
L/s
Enter 0 to omit a valve, baffle or other restriction.

Live readout

Viscous / continuum
Tube C130.6L/sChamber speed7.538L/sUtilization94.23%ID for 80%15.48mmChamberTubePumpID 22 mmChamber speed · L/s vs ID · mm048018.737.4FlowViscousPump speed8 L/s80% target6.4 L/s
Molecular conductance
1.468 L/s
Laminar conductance model
130.6 L/s
Molecular transmission
3.336%
Knudsen number Kn
8.88e-4
Regime-adjusted tube conductance
130.6 L/s
Total series conductance
130.6 L/s
Effective chamber speed
7.538 L/s
Pump utilization
94.23%
Minimum inside diameter for 80%
15.48 mm

    Reading this example

    Viscous conductance varies with mean pressure. Re-check the header later in roughing as density falls.

    Model & assumptions

    Tube throughput

    Cₘ = (A v̄/4) / (1 + 3L/4D) · Cᵥ = πD⁴P̄/(128ηL)

    The aperture-to-long-tube resistance approximation approaches Clausing’s long-tube limit. It is a simplified short-tube correction. The viscous model assumes isothermal, fully developed laminar flow.

    Chamber speed

    1/Cₜ = 1/C + 1/C₂ · 1/Sₑ = 1/Sₚ + 1/Cₜ

    Transition uses a logarithmic Knudsen weight between the two limits. The 80% search requires Cₜ ≥ 4Sₚ. A fixed series restriction at or below 4Sₚ makes the 80% target unattainable by enlarging the tube alone.